cmmEDFAAttrType — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
EDFA DDM for variables.
{1 3 6 1 4 1 36673 100 1 22 1 2 1 1}
EDFA DDM for variables.
QSFP EDFA DDM for variables.
Status in source: current.
Names: cmmEDFAAttrType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cmmEDFAAttrType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"temperature",
"(",
"1",
")",
",",
"voltage",
"(",
"2",
")",
",",
"inputpower",
"(",
"3",
")",
",",
"outputpower",
"(",
"4",
")",
",",
"pumpbias",
"(",
"5",
")",
",",
"gain",
"(",
"6",
")",
"}",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"EDFA DDM for variables.\"",
"::=",
"{",
"cmmEDFADDMEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"temperature",
1
],
[
"voltage",
2
],
[
"inputpower",
3
],
[
"outputpower",
4
],
[
"pumpbias",
5
],
[
"gain",
6
]
]
]
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"EDFA DDM for variables."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: IPI-CMM-EDFA-MIB
cmmEDFAAttrType OBJECT-TYPE
SYNTAX INTEGER {
temperature(1),
voltage(2),
inputpower(3),
outputpower(4),
pumpbias(5),
gain(6)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"EDFA DDM for variables."
::= { cmmEDFADDMEntry 1 }{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi'], 'SNMPv2-SMI-MIB': ['MODULE-IDENTITY', 'Counter32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE'], 'IPI-CMM-CHASSIS-MIB': ['cmmChassisObject', 'cmmStackUnitIndex', 'cmmTransIndex']}Related source files and packages:
Downloaded: 2026-10-24T02:14:23.836191+00:00.
Status in source: current.
Names: cmmQSFPEDFAAttrType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cmmQSFPEDFAAttrType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"temperature",
"(",
"1",
")",
",",
"voltage",
"(",
"2",
")",
",",
"inputpower",
"(",
"3",
")",
",",
"outputpower",
"(",
"4",
")",
",",
"pumpbias",
"(",
"5",
")",
",",
"gain",
"(",
"6",
")",
"}",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"QSFP EDFA DDM for variables.\"",
"::=",
"{",
"cmmQSFPEDFADDMEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"temperature",
1
],
[
"voltage",
2
],
[
"inputpower",
3
],
[
"outputpower",
4
],
[
"pumpbias",
5
],
[
"gain",
6
]
]
]
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"QSFP EDFA DDM for variables."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: IPI-CMM-QSFP-EDFA-MIB
cmmQSFPEDFAAttrType OBJECT-TYPE
SYNTAX INTEGER {
temperature(1),
voltage(2),
inputpower(3),
outputpower(4),
pumpbias(5),
gain(6)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"QSFP EDFA DDM for variables."
::= { cmmQSFPEDFADDMEntry 1 }{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'Counter32', 'enterprises', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi'], 'IPI-CMM-CHASSIS-MIB': ['cmmChassisObject', 'cmmStackUnitIndex', 'cmmTransIndex']}Related source files and packages:
Downloaded: 2026-10-24T02:14:23.840191+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.36673.100.1.22.1.2.1.2 | cmmEDFAValue, cmmQSFPEDFAValue | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.22.1.2.1.3 | cmmEDFAAlertMax, cmmQSFPEDFAAlertMax | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.22.1.2.1.4 | cmmEDFACriticalMax, cmmQSFPEDFACriticalMax | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.22.1.2.1.5 | cmmEDFACriticalMin, cmmQSFPEDFACriticalMin | 0 | 0 | |
| 1.3.6.1.4.1.36673.100.1.22.1.2.1.6 | cmmEDFAAlertMin, cmmQSFPEDFAAlertMin | 0 | 0 |