Reference record for OID 1.3.6.1.4.1.36673.100.1.3.1.26

Parent
1.3.6.1.4.1.36673.100.1.3.1 (cmmAlarmMibNotifications)
Node code
26
Node name
cmmHardDiskUsageRisingAlert
Numeric OID
1.3.6.1.4.1.36673.100.1.3.1.26
URN notation
urn:oid:1.3.6.1.4.1.36673.100.1.3.1.26
ASN.1 notation

{1 3 6 1 4 1 36673 100 1 3 1 26}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmHardDiskUsageRisingAlert(26)}
OID-IRI notation
  • /1/3/6/1/4/1/36673/100/1/3/1/26
  • /ISO/Identified-Organization/6/1/4/1/36673/100/1/3/1/26
  • /ISO/3/6/1/4/1/36673/100/1/3/1/26
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/enterprises/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/enterprises/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/vendor-objects/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/identified-organization/dod/internet/private/vendor-objects/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/enterprises/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/enterprises/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/ldap-enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/ldap-enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/vendor-objects/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • /iso/org/dod/internet/private/vendor-objects/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmHardDiskUsageRisingAlert
  • Additional combinations skipped.

Descriptions

cmmHardDiskUsageRisingAlert — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Trap to send when Hard Disk usage exceeds alert threshold.

Source records

cmmHardDiskUsageRisingAlert

Status in source: current.

Names: cmmHardDiskUsageRisingAlert

Technical details
{
  "smi_kind": "NOTIFICATION-TYPE",
  "definition": [
    "cmmHardDiskUsageRisingAlert",
    "NOTIFICATION-TYPE",
    "OBJECTS",
    "{",
    "cmmStackUnitIndex",
    ",",
    "cmmSysHarddiskUsedMem",
    ",",
    "cmmSysHarddiskUsageAlertThreshold",
    "}",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Trap to send when Hard Disk usage exceeds alert threshold.\"",
    "::=",
    "{",
    "cmmAlarmMibNotifications",
    "26",
    "}"
  ],
  "syntax_tree": [
    [
      "Objects",
      [
        "cmmStackUnitIndex",
        "cmmSysHarddiskUsedMem",
        "cmmSysHarddiskUsageAlertThreshold"
      ]
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Trap to send when Hard Disk usage exceeds alert threshold."
    ],
    null
  ]
}
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: IPI-CMM-CHASSIS-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: IPI-CMM-CHASSIS-MIB

    Published definition
    cmmHardDiskUsageRisingAlert  NOTIFICATION-TYPE
            OBJECTS       {
                          cmmStackUnitIndex,
                          cmmSysHarddiskUsedMem,
                          cmmSysHarddiskUsageAlertThreshold
                         }
            STATUS       current
            DESCRIPTION
                "Trap to send when Hard Disk usage exceeds alert threshold."
            ::= { cmmAlarmMibNotifications 26 }
    Module imports
    {'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE', 'enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi']}

    Related source files and packages:


    Source location: IPI-CMM-CHASSIS-MIB::cmmHardDiskUsageRisingAlert.
    Source version and references

    Same file in Observium Community.

    Downloaded: 2026-10-24T02:14:15.518300+00:00.

  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive.

    Module: IPI-CMM-CHASSIS-MIB

    Published definition
    cmmHardDiskUsageRisingAlert  NOTIFICATION-TYPE
            OBJECTS       {
                          cmmStackUnitIndex,
                          cmmSysHarddiskUsedMem,
                          cmmSysHarddiskUsageAlertThreshold
                         }
            STATUS       current
            DESCRIPTION
                "Trap to send when Hard Disk usage exceeds alert threshold."
            ::= { cmmAlarmMibNotifications 26 }
    Module imports
    {'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE', 'enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi']}

    Related source files and packages:


    Source location: IPI-CMM-CHASSIS-MIB::cmmHardDiskUsageRisingAlert.
    Source version and references

    Downloaded: 2026-10-24T02:14:23.853191+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.36673)

Vishwas Manral

Siblings (128)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.36673.100.1.3.1.1 cmmCpuLoad15MinAlert00
1.3.6.1.4.1.36673.100.1.3.1.2 cmmCpuLoad5MinAlert00
1.3.6.1.4.1.36673.100.1.3.1.3 cmmCpuLoad1MinCritical00
1.3.6.1.4.1.36673.100.1.3.1.4 cmmCpuLoad1MinAlert00
1.3.6.1.4.1.36673.100.1.3.1.5 cmmCpuLoad1MinCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.6 cmmCpuLoad15MinAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.7 cmmCpuLoad5MinAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.8 cmmCpuLoad1MinAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.9 cmmCpuCoreUtilHighCritical00
1.3.6.1.4.1.36673.100.1.3.1.10 cmmCpuCoreUtilHighAlert00
1.3.6.1.4.1.36673.100.1.3.1.11 cmmCpuCoreUtilHighCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.12 cmmCpuCoreUtilHighAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.21 cmmRamUsageRisingCritical00
1.3.6.1.4.1.36673.100.1.3.1.22 cmmRamUsageRisingAlert00
1.3.6.1.4.1.36673.100.1.3.1.23 cmmRamUsageCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.24 cmmRamUsageAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.25 cmmHardDiskUsageRisingCritical00
1.3.6.1.4.1.36673.100.1.3.1.27 cmmHardDiskUsageCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.28 cmmHardDiskUsageAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.29 cmmSysHardDiskRemainLifeRisingAlert00
1.3.6.1.4.1.36673.100.1.3.1.30 cmmSysHardDiskRemainLifeRisingCritical00
1.3.6.1.4.1.36673.100.1.3.1.31 cmmSysHardDiskAvailableReservedSpaceAlert00
1.3.6.1.4.1.36673.100.1.3.1.32 cmmSysHardDiskAvailableReservedSpaceCritical00
1.3.6.1.4.1.36673.100.1.3.1.33 cmmSysHardDiskReallocSectorsCountAlert00
1.3.6.1.4.1.36673.100.1.3.1.34 cmmSysHardDiskUncorrectableSectorCountCritical00
1.3.6.1.4.1.36673.100.1.3.1.35 cmmSysHardDiskActivityMonitoringReadAlert00
1.3.6.1.4.1.36673.100.1.3.1.36 cmmSysHardDiskActivityMonitoringReadRecovery00
1.3.6.1.4.1.36673.100.1.3.1.37 cmmSysHardDiskActivityMonitoringWriteAlert00
1.3.6.1.4.1.36673.100.1.3.1.38 cmmSysHardDiskActivityMonitoringWriteRecovery00
1.3.6.1.4.1.36673.100.1.3.1.39 cmmSysHardDiskStorageStatusNotification00
1.3.6.1.4.1.36673.100.1.3.1.41 cmmTemperatureLowEmergency00
1.3.6.1.4.1.36673.100.1.3.1.42 cmmTemperatureHighEmergency00
1.3.6.1.4.1.36673.100.1.3.1.43 cmmTemperatureLowCritical00
1.3.6.1.4.1.36673.100.1.3.1.44 cmmTemperatureHighCritical00
1.3.6.1.4.1.36673.100.1.3.1.45 cmmTemperatureLowAlert00
1.3.6.1.4.1.36673.100.1.3.1.46 cmmTemperatureHighAlert00
1.3.6.1.4.1.36673.100.1.3.1.47 cmmTemperatureHighCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.48 cmmTemperatureLowCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.49 cmmTemperatureHighAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.50 cmmTemperatureLowAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.61 cmmPsuInsertedNotify00
1.3.6.1.4.1.36673.100.1.3.1.62 cmmPsuRemovedCritical00
1.3.6.1.4.1.36673.100.1.3.1.63 cmmPsuAcFailedCritical00
1.3.6.1.4.1.36673.100.1.3.1.64 cmmPsuAcRecover00
1.3.6.1.4.1.36673.100.1.3.1.65 cmmPsu12vPgFailedCritical00
1.3.6.1.4.1.36673.100.1.3.1.66 cmmPsu12vPgRecover00
1.3.6.1.4.1.36673.100.1.3.1.67 cmmSysPSUInputVoltageHighAlert00
1.3.6.1.4.1.36673.100.1.3.1.68 cmmSysPSUInputVoltageLowAlert00
1.3.6.1.4.1.36673.100.1.3.1.69 cmmSysPSUInputVoltageHighCritical00
1.3.6.1.4.1.36673.100.1.3.1.70 cmmSysPSUInputVoltageLowCritical00