The health check task has detected a power supply running in warning or alarm range.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Circitor
OID reference
1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.113
The health check task has detected a power supply running in warning or alarm range.
Identification
{1 3 6 1 4 1 3764 1 1 400 10 10 1000 0 113}
Available source records contain 2 distinct definitions; some records may not include a definition.
envPowerEvent TRAP-TYPE
ENTERPRISE trapDefinition
VARIABLES
{
componentId ,
paTrapSequenceNumber,
paTime,
paProducer,
paEventClass,
paEventCode,
paSeq,
paEventVars
}
DESCRIPTION
"The health check task has detected a power
supply running in warning or alarm range."
::= 113envPowerEvent TRAP-TYPE
ENTERPRISE trapDefinition
VARIABLES
{
componentId,
paTrapSequenceNumber,
paTime,
paProducer,
paEventClass,
paEventCode,
paSeq,
paEventVars
}
DESCRIPTION
"The health check task has detected a power
supply running in warning or alarm range."
::= 113
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The health check task has detected a power supply running in warning or alarm range.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Circitor
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: unspecified.
Names: envPowerEvent
{
"smi_kind": "TRAP-TYPE",
"definition": [
"envPowerEvent",
"TRAP-TYPE",
"ENTERPRISE",
"trapDefinition",
"VARIABLES",
"{",
"componentId",
",",
"paTrapSequenceNumber",
",",
"paTime",
",",
"paProducer",
",",
"paEventClass",
",",
"paEventCode",
",",
"paSeq",
",",
"paEventVars",
"}",
"DESCRIPTION",
"\"The health check task has detected a power supply running in warning or alarm range.\"",
"::=",
"113"
],
"syntax_tree": [
[
"objectIdentifier",
[
"trapDefinition"
]
],
[
"VarTypes",
[
"componentId",
"paTrapSequenceNumber",
"paTime",
"paProducer",
"paEventClass",
"paEventCode",
"paSeq",
"paEventVars"
]
],
[
"DESCRIPTION",
"The health check task has detected a power supply running in warning or alarm range."
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: ADIC-SANMGR-PROXY-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['TimeTicks', 'IpAddress', 'Gauge', 'enterprises', 'experimental'], 'RFC1213-MIB': ['DisplayString'], 'ADIC-INTELLIGENT-STORAGE-MIB': ['network', 'componentId', 'RowStatus', 'Boolean']}Related source files and packages:
Module: ADIC-SANMGR-PROXY-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['TimeTicks', 'IpAddress', 'Gauge', 'enterprises', 'experimental'], 'RFC1213-MIB': ['DisplayString'], 'ADIC-INTELLIGENT-STORAGE-MIB': ['adic', 'productAgentInfo', 'globalData', 'components', 'software', 'hardware', 'sml', 'network', 'componentId', 'AdicAgentStatus', 'AdicGlobalId']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.110 | fcLinkStatusChangeEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.111 | newFcTranferErrorsEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.112 | envFanEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.114 | envTemperatureEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.115 | eccMemoryHealthCheckEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.116 | eccMemoryScrubberEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.118 | deviceRecoverEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.150 | logWillOverwriteEvent | 0 | 0 | |
| 1.3.6.1.4.1.3764.1.1.400.10.10.1000.0.4444 | bootCompletedEvent | 0 | 0 |