Data maintained by the MME Resource Manager is out of synchronization.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Affirmed Networks MIB copies (Observium Community)
OID reference
1.3.6.1.4.1.37963.4.0.6.1.133824513
Data maintained by the MME Resource Manager is out of synchronization.
Identification
{1 3 6 1 4 1 37963 4 0 6 1 133824513}
The displayed source records contain one distinct definition. Compare its source records.
anMmeTrapAlarmMmeRm1301 NOTIFICATION-TYPE
OBJECTS { anMmeAlarmState,
anMmeAlarmSeverity,
anMmeEntityTag,
anMmeSubentityInfo,
anMmeLocationGateway,
anMmeReason,
anMmeAlarmDateAndTime,
anMmeGroupKey,
anMmeSequenceNumber,
anMmeFirstEvent,
anMmeLastEvent,
anMmeLocation,
anMmeService,
anMmeAlarmIndex }
STATUS current
DESCRIPTION
"Data maintained by the MME Resource Manager is out of synchronization."
-- REPAIR-ACTION
-- "No immediate action required. The active and standby callP VMs (if available)
-- automatically attempt to resynchronize with each other. If condition persists,
-- contact product support organization."
-- ENTITY-TYPE
-- "system"
--
::= { anMmeTrapAlarms 133824513 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Data maintained by the MME Resource Manager is out of synchronization.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Affirmed Networks MIB copies (Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: anMmeTrapAlarmMmeRm1301
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"anMmeTrapAlarmMmeRm1301",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"anMmeAlarmState",
",",
"anMmeAlarmSeverity",
",",
"anMmeEntityTag",
",",
"anMmeSubentityInfo",
",",
"anMmeLocationGateway",
",",
"anMmeReason",
",",
"anMmeAlarmDateAndTime",
",",
"anMmeGroupKey",
",",
"anMmeSequenceNumber",
",",
"anMmeFirstEvent",
",",
"anMmeLastEvent",
",",
"anMmeLocation",
",",
"anMmeService",
",",
"anMmeAlarmIndex",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Data maintained by the MME Resource Manager is out of synchronization.\"",
"::=",
"{",
"anMmeTrapAlarms",
"133824513",
"}"
],
"syntax_tree": [
[
"Objects",
[
"anMmeAlarmState",
"anMmeAlarmSeverity",
"anMmeEntityTag",
"anMmeSubentityInfo",
"anMmeLocationGateway",
"anMmeReason",
"anMmeAlarmDateAndTime",
"anMmeGroupKey",
"anMmeSequenceNumber",
"anMmeFirstEvent",
"anMmeLastEvent",
"anMmeLocation",
"anMmeService",
"anMmeAlarmIndex"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Data maintained by the MME Resource Manager is out of synchronization."
],
null
]
}Vendor MIB copy from the Observium Community archive. Affirmed Networks support.
Module: AFFIRMED-MME-TRAPS-MIB
See published definition above
{'IPV6-TC': ['Ipv6Address'], 'ALARM-MIB': ['alarmListName', 'alarmModelIndex', 'alarmModelState', 'alarmActiveDateAndTime', 'alarmActiveIndex'], 'SNMPv2-TC': ['PhysAddress', 'DisplayString', 'DateAndTime', 'TruthValue', 'AutonomousType', 'RowPointer', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'Gauge32', 'Unsigned32', 'Counter64', 'enterprises'], 'RFC1155-SMI': ['mgmt', 'NetworkAddress', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'ITU-ALARM-TC-MIB': ['ItuPerceivedSeverity'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: AFFIRMED-MME-TRAPS-MIB
{'IPV6-TC': ['Ipv6Address'], 'ALARM-MIB': ['alarmListName', 'alarmModelIndex', 'alarmModelState', 'alarmActiveDateAndTime', 'alarmActiveIndex'], 'SNMPv2-TC': ['PhysAddress', 'DisplayString', 'DateAndTime', 'TruthValue', 'AutonomousType', 'RowPointer', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'Gauge32', 'Unsigned32', 'Counter64', 'enterprises'], 'RFC1155-SMI': ['mgmt', 'NetworkAddress', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'ITU-ALARM-TC-MIB': ['ItuPerceivedSeverity'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Registration