UPS will shutdown and turn back on when the variable is set to rebootUps(2). It is no effective to set this value to noRebootUps(1).
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3808.1.1.1.6.2.2
UPS will shutdown and turn back on when the variable is set to rebootUps(2). It is no effective to set this value to noRebootUps(1).
Identification
{1 3 6 1 4 1 3808 1 1 1 6 2 2}
| Value | Name |
|---|---|
| 1 | noRebootUps |
| 2 | rebootUps |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.3808.1.1.1.6.2.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
upsAdvanceControlRebootUps OBJECT-TYPE
SYNTAX INTEGER {
noRebootUps(1),
rebootUps(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UPS will shutdown and turn back on when the variable is
set to rebootUps(2).
It is no effective to set this value to noRebootUps(1)."
::= { upsAdvanceControl 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
UPS will shutdown and turn back on when the variable is set to rebootUps(2). It is no effective to set this value to noRebootUps(1).
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: upsAdvanceControlRebootUps
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"upsAdvanceControlRebootUps",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"noRebootUps",
"(",
"1",
")",
",",
"rebootUps",
"(",
"2",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"UPS will shutdown and turn back on when the variable is set to rebootUps(2). It is no effective to set this value to noRebootUps(1).\"",
"::=",
"{",
"upsAdvanceControl",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"noRebootUps",
1
],
[
"rebootUps",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"UPS will shutdown and turn back on when the variable is set to rebootUps(2). It is no effective to set this value to noRebootUps(1)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CPS-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: CPS-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3808.1.1.1.6.2.1 | upsAdvanceControlUpsOff | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.1.6.2.3 | upsAdvanceControlUpsSleep | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.1.6.2.4 | upsAdvanceControlSimulatePowerFail | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.1.6.2.5 | upsAdvanceControlFlashAndBeep | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.1.6.2.6 | upsAdvanceControlTurnOnUPS | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.1.6.2.7 | upsAdvanceSleepAfterDelay | 0 | 0 |