Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3808.1.1.3.5.6
Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
Identification
{1 3 6 1 4 1 3808 1 1 3 5 6}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ePDUStatusOutletTable OBJECT-TYPE
SYNTAX SEQUENCE OF OutletEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU."
::= { ePDUStatus 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: ePDUStatusOutletTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ePDUStatusOutletTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"OutletEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.\"",
"::=",
"{",
"ePDUStatus",
"6",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"OutletEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CPS-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: CPS-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3808.1.1.3.5.6.1 | ePDUStatusOutletEntry | 3 | 3 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3808.1.1.3.5.1 | ePDUStatusBankTableSize | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.3.5.2 | ePDUStatusBankTable | 1 | 4 | |
| 1.3.6.1.4.1.3808.1.1.3.5.3 | ePDUStatusPhaseTableSize | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.3.5.4 | ePDUStatusPhaseTable | 1 | 4 | |
| 1.3.6.1.4.1.3808.1.1.3.5.5 | ePDUStatusOutletTableSize | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.3.5.7 | ePDUStatusInputVoltage | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.3.5.8 | ePDUStatusInputFrequency | 0 | 0 |