Indicates the date and time of the last device energy meter reset.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3808.1.1.6.6.2.4.1.12
Indicates the date and time of the last device energy meter reset.
Identification
{1 3 6 1 4 1 3808 1 1 6 6 2 4 1 12}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ePDU2OutletMeteredStatusEnergyStart OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the date and time of the last device energy
meter reset."
::= {ePDU2OutletMeteredStatusEntry 12}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the date and time of the last device energy meter reset.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: ePDU2OutletMeteredStatusEnergyStart
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ePDU2OutletMeteredStatusEnergyStart",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Indicates the date and time of the last device energy meter reset.\"",
"::=",
"{",
"ePDU2OutletMeteredStatusEntry",
"12",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Indicates the date and time of the last device energy meter reset."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CPS-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: CPS-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.1 | ePDU2OutletMeteredStatusIndex | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.2 | ePDU2OutletMeteredStatusModuleIndex | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.3 | ePDU2OutletMeteredStatusNumber | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.4 | ePDU2OutletMeteredStatusName | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.5 | ePDU2OutletMeteredStatusAlarm | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.6 | ePDU2OutletMeteredStatusLoad | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.7 | ePDU2OutletMeteredStatusActivePower | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.8 | ePDU2OutletMeteredStatusPeakPower | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.9 | ePDU2OutletMeteredStatusPeakPowerTimestamp | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.10 | ePDU2OutletMeteredStatusPeakPowerStartTime | 0 | 0 | |
| 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.11 | ePDU2OutletMeteredStatusEnergy | 0 | 0 |