OID reference

saBPDUGuardTrap

1.3.6.1.4.1.3833.1.1.14.1.0.8

Description

This trap is sent if on this port an BPDU guard functionality is enabled (globally or only for this port) and an (R)STP BPDU are received on this port. That means when saIfaceStpBpduGuardStatus is set to true(1) for this port. Then IfAdminStatus for this port is set to down(2). If needed, it must be changed by hand to…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.1.0 (0)
Node code
8
Node name
saBPDUGuardTrap
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.3833.1.1.14.1.0.8
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.1.0.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 1 0 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) 0 saBPDUGuardTrap(8)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/1/0/8
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/1/0/8
  • /ISO/3/6/1/4/1/3833/1/1/14/1/0/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/0/saBPDUGuardTrap
  • Additional combinations skipped.

The displayed source records contain one distinct definition. Compare its source records.

saBPDUGuardTrap TRAP-TYPE
 	ENTERPRISE	saChassis
 	VARIABLES	{ saIfaceStpBpduGuardStatus }
 	DESCRIPTION "This trap is sent if on this port an BPDU guard 
                  functionality is enabled (globally or only for this port) 
                  and an (R)STP BPDU are received on this port. That means when 
                  saIfaceStpBpduGuardStatus is set to true(1) for this port.
                  Then IfAdminStatus for this port is set to down(2). 
                  If needed, it must be changed by hand to up(1)"
 	::= 8

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This trap is sent if on this port an BPDU guard functionality is enabled (globally or only for this port) and an (R)STP BPDU are received on this port. That means when saIfaceStpBpduGuardStatus is set to true(1) for this port. Then IfAdminStatus for this port is set to down(2). If needed, it must be changed by hand to up(1)

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saBPDUGuardTrap · unspecifiedSchneider Electric Transparent Factory official MIB1 source

Status in source: unspecified.

Names: saBPDUGuardTrap

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "saBPDUGuardTrap",
    "TRAP-TYPE",
    "ENTERPRISE",
    "saChassis",
    "VARIABLES",
    "{",
    "saIfaceStpBpduGuardStatus",
    "}",
    "DESCRIPTION",
    "\"This trap is sent if on this port an BPDU guard functionality is enabled (globally or only for this port) and an (R)STP BPDU are received on this port. That means when saIfaceStpBpduGuardStatus is set to true(1) for this port. Then IfAdminStatus for this port is set to down(2). If needed, it must be changed by hand to up(1)\"",
    "::=",
    "8"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "saChassis"
      ]
    ],
    [
      "VarTypes",
      [
        "saIfaceStpBpduGuardStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap is sent if on this port an BPDU guard functionality is enabled (globally or only for this port) and an (R)STP BPDU are received on this port. That means when saIfaceStpBpduGuardStatus is set to true(1) for this port. Then IfAdminStatus for this port is set to down(2). If needed, it must be changed by hand to up(1)"
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.1.0.1 saGroupMapChange00
1.3.6.1.4.1.3833.1.1.14.1.0.2 saPowerSupply00
1.3.6.1.4.1.3833.1.1.14.1.0.3 saFan00
1.3.6.1.4.1.3833.1.1.14.1.0.4 saSignallingRelay00
1.3.6.1.4.1.3833.1.1.14.1.0.5 saStandby00
1.3.6.1.4.1.3833.1.1.14.1.0.7 saModuleMapChange00
1.3.6.1.4.1.3833.1.1.14.1.0.10 saSigConRelayChange00
1.3.6.1.4.1.3833.1.1.14.1.0.11 saSFPChangeTrap00