Status in source: mandatory.
Names: saSysStpBPDUGuardEnable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saSysStpBPDUGuardEnable",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"enable",
"(",
"1",
")",
",",
"disable",
"(",
"2",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This variable controls the BPDU Guard operation of the entire switch (globally). To control the BPDU Guard function of each port use saIfaceStpBpduGuardEnable. If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)), and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled and an BPDU are received on the port, then saIfaceStpBpduGuardStatus is set to true(1) for this port and IfAdminStatus is set to down(2) for this port. Variable saIfaceStpBpduGuardStatus can be resetted (to their original values (=false)) with switching BPDU guard functionality globally off (saSysStpBPDUGuardEnable=disable(2)). IfAdminStatus can be again resetted to to their original values up() only manually. The default value of saSysStpBPDUGuardEnable is disable(2).\"",
"::=",
"{",
"saSystemTable",
"32",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"enable",
1
],
[
"disable",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This variable controls the BPDU Guard operation of the entire switch (globally). To control the BPDU Guard function of each port use saIfaceStpBpduGuardEnable. If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)), and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled and an BPDU are received on the port, then saIfaceStpBpduGuardStatus is set to true(1) for this port and IfAdminStatus is set to down(2) for this port. Variable saIfaceStpBpduGuardStatus can be resetted (to their original values (=false)) with switching BPDU guard functionality globally off (saSysStpBPDUGuardEnable=disable(2)). IfAdminStatus can be again resetted to to their original values up() only manually. The default value of saSysStpBPDUGuardEnable is disable(2)."
],
null,
null,
null,
null
]
}
- Schneider Electric Transparent Factory official MIB
· Publisher's source file: Schneider Electric SchneiderTFE-V01-04.mib — M580 support package
Module: TFPRIVATE-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}
Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.