This table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifMauIfIndex.
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.14.1.10.4
This table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifMauIfIndex.
Identification
{1 3 6 1 4 1 3833 1 1 14 1 10 4}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
saSigLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaSigLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains all variables to mask an alarm for the
signalling relay, produced by a link. The index for a link
corresponds with ifMauIfIndex."
::= { saNXSext 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifMauIfIndex.
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: saSigLinkTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saSigLinkTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"SaSigLinkEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifMauIfIndex.\"",
"::=",
"{",
"saNXSext",
"4",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"SaSigLinkEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifMauIfIndex."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.1.10.4.1 | saSigLinkEntry | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.1.10.1 | saNXSOperMode | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.2 | saNXSConfigError | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.3 | saNXSSigRelayState | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.5 | saSigTrapReason | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.6 | saSigReasonIndex | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.7 | saNXSTopologyGroup | 2 | 5 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.8 | saNXSConnectionMirroringGroup | 3 | 3 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.9 | saNXSDisableLearningGroup | 1 | 1 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.10 | saNXSSigRelayGroup | 2 | 2 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.11 | saNXSVlanGroup | 2 | 2 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.12 | saNXSSelftestGroup | 2 | 2 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.13 | saNXSPSGroup | 1 | 1 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.14 | saNXSRedundancyGroup | 1 | 1 | |
| 1.3.6.1.4.1.3833.1.1.14.1.10.16 | saNXSFDBGroup | 1 | 3 |