OID reference
saFanEntry
1.3.6.1.4.1.3833.1.1.14.1.3.1
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.3833.1.1.14.1.3 (saFanTable)
- Node code
- 1
- Node name
- saFanEntry
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.3833.1.1.14.1.3.1
- URN notation
- urn:oid:1.3.6.1.4.1.3833.1.1.14.1.3.1
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 3833 1 1 14 1 3 1}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saFanTable(3) saFanEntry(1)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/3833/1/1/14/1/3/1
- /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/1/3/1
- /ISO/3/6/1/4/1/3833/1/1/14/1/3/1
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/saFanTable/saFanEntry
- Additional combinations skipped.
SNMP properties
- Value type
- SaFanEntry
- Maximum access defined by MIB
- not-accessible
- Status in MIB
- mandatory
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
saFanEntry OBJECT-TYPE
SYNTAX SaFanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { saFanSysID, saFanID }
::= { saFanTable 1 }
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Definitions without a descriptionSchneider Electric Transparent Factory official MIB
saFanEntry · mandatorySchneider Electric Transparent Factory official MIB
Status in source: mandatory.
Names: saFanEntry
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saFanEntry",
"OBJECT-TYPE",
"SYNTAX",
"SaFanEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"\"",
"INDEX",
"{",
"saFanSysID",
",",
"saFanID",
"}",
"::=",
"{",
"saFanTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"SaFanEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
""
],
null,
null,
[
"INDEX",
[
[
0,
"saFanSysID"
],
[
0,
"saFanID"
]
]
],
null
]
}- Schneider Electric Transparent Factory official MIB
· Publisher's source file: Schneider Electric SchneiderTFE-V01-04.mib — M580 support package
Module: TFPRIVATE-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)
Direct children (3)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.1.3.1.1 | saFanSysID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.3.1.2 | saFanID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.3.1.3 | saFanState | 0 | 0 |