This trap is sent if a user attemps to set the same static unicast address at more than one agent of a chassis
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.14.2.0.3
This trap is sent if a user attemps to set the same static unicast address at more than one agent of a chassis
Identification
{1 3 6 1 4 1 3833 1 1 14 2 0 3}
The displayed source records contain one distinct definition. Compare its source records.
saDuplicateStaticAddressTrap TRAP-TYPE
ENTERPRISE saAgent
VARIABLES { dot1dStaticAddress }
DESCRIPTION "This trap is sent if a user attemps to set the same static unicast
address at more than one agent of a chassis"
::= 3
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This trap is sent if a user attemps to set the same static unicast address at more than one agent of a chassis
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: saDuplicateStaticAddressTrap
{
"smi_kind": "TRAP-TYPE",
"definition": [
"saDuplicateStaticAddressTrap",
"TRAP-TYPE",
"ENTERPRISE",
"saAgent",
"VARIABLES",
"{",
"dot1dStaticAddress",
"}",
"DESCRIPTION",
"\"This trap is sent if a user attemps to set the same static unicast address at more than one agent of a chassis\"",
"::=",
"3"
],
"syntax_tree": [
[
"objectIdentifier",
[
"saAgent"
]
],
[
"VarTypes",
[
"dot1dStaticAddress"
]
],
[
"DESCRIPTION",
"This trap is sent if a user attemps to set the same static unicast address at more than one agent of a chassis"
],
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.2.0.1 | saTemperatureTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.2.0.2 | saLoginTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.2.0.4 | saBackUpConfigAdapterTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.2.0.5 | saRelayDuplicateIPTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.2.0.6 | saSNTPTrap | 0 | 0 |