Status in source: mandatory.
Names: saNetSNTPTimeAdjustThreshold
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saNetSNTPTimeAdjustThreshold",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The threshold in milli-seconds whether to decide to set the received SNTP time directly to the local clock or not. If the saNetSNTPTimeAdjustThreshold value is 0, the received SNTP time will be set directly to the local clock every time a SNTP message is received. If the difference between the local clock time and the received SNTP time is fewer than the saNetSNTPTimeAdjustThreshold value, the local clock will not be set. If the difference between the local clock time and the received SNTP time is equal or larger than the saNetSNTPTimeAdjustThreshold value, the local clock will be set.\"",
"::=",
"{",
"saNetSNTPGroup",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The threshold in milli-seconds whether to decide to set the received SNTP time directly to the local clock or not. If the saNetSNTPTimeAdjustThreshold value is 0, the received SNTP time will be set directly to the local clock every time a SNTP message is received. If the difference between the local clock time and the received SNTP time is fewer than the saNetSNTPTimeAdjustThreshold value, the local clock will not be set. If the difference between the local clock time and the received SNTP time is equal or larger than the saNetSNTPTimeAdjustThreshold value, the local clock will be set."
],
null,
null,
null,
null
]
}
- Schneider Electric Transparent Factory official MIB
· Publisher's source file: Schneider Electric SchneiderTFE-V01-04.mib — M580 support package
Module: TFPRIVATE-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}
Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support package