This variable reflects the user ID of a connected user actually seen on this port. If there is no user connected the value will be 0x00:00:00:00:00:00.
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.14.3.4.1.6
This variable reflects the user ID of a connected user actually seen on this port. If there is no user connected the value will be 0x00:00:00:00:00:00.
Identification
{1 3 6 1 4 1 3833 1 1 14 3 4 1 6}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
saPortSecConnectedUserID OBJECT-TYPE
SYNTAX MemberID
ACCESS read-only
STATUS mandatory
DESCRIPTION "This variable reflects the user ID of a connected user
actually seen on this port. If there is no user connected
the value will be 0x00:00:00:00:00:00."
::= { saPortSecurityEntry 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This variable reflects the user ID of a connected user actually seen on this port. If there is no user connected the value will be 0x00:00:00:00:00:00.
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: saPortSecConnectedUserID
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saPortSecConnectedUserID",
"OBJECT-TYPE",
"SYNTAX",
"MemberID",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This variable reflects the user ID of a connected user actually seen on this port. If there is no user connected the value will be 0x00:00:00:00:00:00.\"",
"::=",
"{",
"saPortSecurityEntry",
"6",
"}"
],
"syntax_tree": [
[
"row",
"MemberID"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This variable reflects the user ID of a connected user actually seen on this port. If there is no user connected the value will be 0x00:00:00:00:00:00."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.1 | saPortSecSlotID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.2 | saPortSecPortID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.3 | saPortSecPermission | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.4 | saPortSecAllowedUserID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.5 | saPortSecAllowedGroupIDs | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.7 | saPortSecAction | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.8 | saPortSecAutoReconfigure | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.9 | saPortSecPortStatus | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.3.4.1.10 | saPortSecAllowedUserIPID | 0 | 0 |