saLLDPIfaceFDBMode

1.3.6.1.4.1.3833.1.1.14.7.1.2.1.4

Description

If configured to lldpOnly(1), only received LLDP messages will be used to populate the LLDP-MIB's remTable. If configured to macOnly(2), learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to both(3), both received LLDP messages and learne…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.7.1.2.1 (saLLDPInterfaceEntry)
Node code
4
Node name
saLLDPIfaceFDBMode
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.1.14.7.1.2.1.4
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.7.1.2.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 7 1 2 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saLLDP(7) saLLDPConfig(1) saLLDPInterfaceTable(2) saLLDPInterfaceEntry(1) saLLDPIfaceFDBMode(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/7/1/2/1/4
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/7/1/2/1/4
  • /ISO/3/6/1/4/1/3833/1/1/14/7/1/2/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saLLDP/saLLDPConfig/saLLDPInterfaceTable/saLLDPInterfaceEntry/saLLDPIfaceFDBMode
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1lldpOnly
2macOnly
3both
4autoDetect

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In TFPRIVATE-MIB, the row index consists of these components in order:

  1. saLLDPIfaceGroupID (INTEGER): one numeric subidentifier for the non-negative value.
  2. saLLDPIfaceID (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.3833.1.1.14.7.1.2.1.4.<saLLDPIfaceGroupID>.<saLLDPIfaceID>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.7.1.2.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saLLDPIfaceFDBMode	OBJECT-TYPE
	    SYNTAX INTEGER { 
	       lldpOnly(1),
	       macOnly(2),
	       both(3),	       
	       autoDetect(4)
	    }
		 ACCESS 	 read-write
		 STATUS 	 mandatory
		 DESCRIPTION
                " If configured to lldpOnly(1), only received LLDP messages
                  will be used to populate the LLDP-MIB's remTable.
				  If configured to macOnly(2), learned mac addresses out of the switch's forwarding database (FDB)
                  will be used to populate the LLDP-MIB's remTable.
				  If configured to both(3), both received LLDP messages
                  and learned mac addresses out of the switch's forwarding database (FDB)
                  will be used to populate the LLDP-MIB's remTable.
				  If configured to autoDetect(4) and LLDP messages are received on this port, 
				  this mode will behave like lldpOnly(1), otherwise it will behave like macOnly(2)."
    -- DEFVAL      { 1 }                
	 ::= { saLLDPInterfaceEntry 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

If configured to lldpOnly(1), only received LLDP messages will be used to populate the LLDP-MIB's remTable. If configured to macOnly(2), learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to both(3), both received LLDP messages and learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to autoDetect(4) and LLDP messages are received on this port, this mode will behave like lldpOnly(1), otherwise it will behave like macOnly(2).

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saLLDPIfaceFDBMode · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: saLLDPIfaceFDBMode

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saLLDPIfaceFDBMode",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "lldpOnly",
    "(",
    "1",
    ")",
    ",",
    "macOnly",
    "(",
    "2",
    ")",
    ",",
    "both",
    "(",
    "3",
    ")",
    ",",
    "autoDetect",
    "(",
    "4",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\" If configured to lldpOnly(1), only received LLDP messages will be used to populate the LLDP-MIB's remTable. If configured to macOnly(2), learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to both(3), both received LLDP messages and learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to autoDetect(4) and LLDP messages are received on this port, this mode will behave like lldpOnly(1), otherwise it will behave like macOnly(2).\"",
    "::=",
    "{",
    "saLLDPInterfaceEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "lldpOnly",
            1
          ],
          [
            "macOnly",
            2
          ],
          [
            "both",
            3
          ],
          [
            "autoDetect",
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "If configured to lldpOnly(1), only received LLDP messages will be used to populate the LLDP-MIB's remTable. If configured to macOnly(2), learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to both(3), both received LLDP messages and learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to autoDetect(4) and LLDP messages are received on this port, this mode will behave like lldpOnly(1), otherwise it will behave like macOnly(2)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (4)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.7.1.2.1.1 saLLDPIfaceGroupID00
1.3.6.1.4.1.3833.1.1.14.7.1.2.1.2 saLLDPIfaceID00
1.3.6.1.4.1.3833.1.1.14.7.1.2.1.3 saLLDPIfaceSaMode00
1.3.6.1.4.1.3833.1.1.14.7.1.2.1.5 saLLDPIfaceMaxNeighbors00