The Designated Root like in dot1dStpDesignatedRoot.
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.15.1.2.15.8.10
The Designated Root like in dot1dStpDesignatedRoot.
Identification
{1 3 6 1 4 1 3833 1 1 15 1 2 15 8 10}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
saAgentStpCstBridgeDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Designated Root like in dot1dStpDesignatedRoot."
::= { saAgentStpCstConfigGroup 10 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The Designated Root like in dot1dStpDesignatedRoot.
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: saAgentStpCstBridgeDesignatedRoot
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saAgentStpCstBridgeDesignatedRoot",
"OBJECT-TYPE",
"SYNTAX",
"BridgeId",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The Designated Root like in dot1dStpDesignatedRoot.\"",
"::=",
"{",
"saAgentStpCstConfigGroup",
"10",
"}"
],
"syntax_tree": [
[
"row",
"BridgeId"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The Designated Root like in dot1dStpDesignatedRoot."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.1 | saAgentStpCstHelloTime | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.2 | saAgentStpCstMaxAge | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.3 | saAgentStpCstRegionalRootId | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.4 | saAgentStpCstRegionalRootPathCost | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.5 | saAgentStpCstRootFwdDelay | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.6 | saAgentStpCstBridgeFwdDelay | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.7 | saAgentStpCstBridgeHelloTime | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.8 | saAgentStpCstBridgeHoldTime | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.9 | saAgentStpCstBridgeMaxAge | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.11 | saAgentStpCstBridgePriority | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.12 | saAgentStpCstBridgeTimeSinceTopologyChange | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.13 | saAgentStpCstBridgeTopChanges | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.14 | saAgentStpCstBridgeRootCost | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.15.8.15 | saAgentStpCstBridgeRootPort | 0 | 0 |