Status in source: mandatory.
Names: saAgentSwitchIGMPSnoopingPortMask
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saAgentSwitchIGMPSnoopingPortMask",
"OBJECT-TYPE",
"SYNTAX",
"SaAgentPortMask",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"IGMP Snooping Port Mask. This allows configuration of IGMP Snooping on selected ports. IGMP Snooping cannot be enabled on an interface that has routing enabled, or is a member of a LAG. If a port which has IGMP Snooping enabled becomes enabled for routing, or is enlisted as a member of a LAG, IGMP Snooping functionality will be disabled on that port. IGMP Snooping functionality will be subsequently be reenabled if routing is disabled or LAG membership is removed from an interface that had previously had IGMP Snooping enabled. To obtain port numbers from interface numbers, use the objects saAgentPortDot1dBasePort and saAgentPortIfIndex in the saAgentPortConfigTable table.\"",
"::=",
"{",
"saAgentSwitchIGMPSnoopingGroup",
"5",
"}"
],
"syntax_tree": [
[
"row",
"SaAgentPortMask"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"IGMP Snooping Port Mask. This allows configuration of IGMP Snooping on selected ports. IGMP Snooping cannot be enabled on an interface that has routing enabled, or is a member of a LAG. If a port which has IGMP Snooping enabled becomes enabled for routing, or is enlisted as a member of a LAG, IGMP Snooping functionality will be disabled on that port. IGMP Snooping functionality will be subsequently be reenabled if routing is disabled or LAG membership is removed from an interface that had previously had IGMP Snooping enabled. To obtain port numbers from interface numbers, use the objects saAgentPortDot1dBasePort and saAgentPortIfIndex in the saAgentPortConfigTable table."
],
null,
null,
null,
null
]
}
- Schneider Electric Transparent Factory official MIB
· Publisher's source file: Schneider Electric SchneiderTFE-V01-04.mib — M580 support package
Module: TFPRIVATE-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}
Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support package
Related source files and packages: