This displays the largest number of entries that have been present in the Multicast Forwarding Database table. This value is also known as the MFDB high-water mark.
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.15.1.2.8.7.4
This displays the largest number of entries that have been present in the Multicast Forwarding Database table. This value is also known as the MFDB high-water mark.
Identification
{1 3 6 1 4 1 3833 1 1 15 1 2 8 7 4}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.15.1.2.8.7.4.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
saAgentSwitchMFDBMostEntriesUsed OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This displays the largest number of entries that have been present
in the Multicast Forwarding Database table. This value is also known
as the MFDB high-water mark."
::= { saAgentSwitchMFDBGroup 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This displays the largest number of entries that have been present in the Multicast Forwarding Database table. This value is also known as the MFDB high-water mark.
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: saAgentSwitchMFDBMostEntriesUsed
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saAgentSwitchMFDBMostEntriesUsed",
"OBJECT-TYPE",
"SYNTAX",
"Gauge",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This displays the largest number of entries that have been present in the Multicast Forwarding Database table. This value is also known as the MFDB high-water mark.\"",
"::=",
"{",
"saAgentSwitchMFDBGroup",
"4",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This displays the largest number of entries that have been present in the Multicast Forwarding Database table. This value is also known as the MFDB high-water mark."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.15.1.2.8.7.1 | saAgentSwitchMFDBTable | 1 | 8 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.8.7.2 | saAgentSwitchMFDBSummaryTable | 1 | 4 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.8.7.3 | saAgentSwitchMFDBMaxTableEntries | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.15.1.2.8.7.5 | saAgentSwitchMFDBCurrentEntries | 0 | 0 |