OID reference

port502AddStackStatTable

1.3.6.1.4.1.3833.1.2.13

Description

Additional stack statistics for Port502 (optional).

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.2 (port502Messaging)
Node code
13
Node name
port502AddStackStatTable
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.2.13
URN notation
urn:oid:1.3.6.1.4.1.3833.1.2.13
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 2 13}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) port502Messaging(2) port502AddStackStatTable(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) port502Messaging(2) port502AddStackStatTable(13)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/2/13
  • /ISO/Identified-Organization/6/1/4/1/3833/1/2/13
  • /ISO/3/6/1/4/1/3833/1/2/13
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/port502Messaging/port502AddStackStatTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/port502Messaging/port502AddStackStatTable
  • Additional combinations skipped.

SNMP properties

Value type
SEQUENCE OF Port502AddStackStatEntry
Maximum access defined by MIB
not-accessible
Status in MIB
current, optional

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Schneider Electric Transparent Factory official MIB

Value type
SEQUENCE OF Port502AddStackStatEntry
Maximum access defined by MIB
not-accessible
Status in MIB
current

Variant 2 — Schneider Electric Transparent Factory official MIB

Value type
SEQUENCE OF Port502AddStackStatEntry
Maximum access defined by MIB
not-accessible
Status in MIB
optional

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

port502AddStackStatTable · current

port502AddStackStatTable OBJECT-TYPE
              SYNTAX SEQUENCE OF Port502AddStackStatEntry
              MAX-ACCESS not-accessible 
              STATUS  current
              DESCRIPTION
                      "Additional stack statistics for Port502 (optional)."
              ::= { port502Messaging 13 }

port502AddStackStatTable · optional

port502AddStackStatTable OBJECT-TYPE
              SYNTAX SEQUENCE OF Port502AddStackStatEntry
              ACCESS not-accessible 
              STATUS  optional
              DESCRIPTION
                      "Additional stack statistics for Port502 (optional)."
              ::= { port502Messaging 13 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Additional stack statistics for Port502 (optional).

Sources for this description

Schneider Electric Transparent Factory official MIB

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB2 records · 2 sources

Description 1

port502AddStackStatTable · currentSchneider Electric Transparent Factory official MIB1 source

Status in source: current.

Names: port502AddStackStatTable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "port502AddStackStatTable",
    "OBJECT-TYPE",
    "SYNTAX",
    "SEQUENCE",
    "OF",
    "Port502AddStackStatEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Additional stack statistics for Port502 (optional).\"",
    "::=",
    "{",
    "port502Messaging",
    "13",
    "}"
  ],
  "syntax_tree": [
    [
      "conceptualTable",
      [
        "row",
        "Port502AddStackStatEntry"
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Additional stack statistics for Port502 (optional)."
    ],
    null,
    null,
    null,
    null
  ]
}
port502AddStackStatTable · optionalSchneider Electric Transparent Factory official MIB1 source

Status in source: optional.

Names: port502AddStackStatTable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "port502AddStackStatTable",
    "OBJECT-TYPE",
    "SYNTAX",
    "SEQUENCE",
    "OF",
    "Port502AddStackStatEntry",
    "ACCESS",
    "not-accessible",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"Additional stack statistics for Port502 (optional).\"",
    "::=",
    "{",
    "port502Messaging",
    "13",
    "}"
  ],
  "syntax_tree": [
    [
      "conceptualTable",
      [
        "row",
        "Port502AddStackStatEntry"
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "Additional stack statistics for Port502 (optional)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.2.13.1 port502AddStackStatEntry22

Siblings (13)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.2.0 port502MessagingV211
1.3.6.1.4.1.3833.1.2.1 port502Status00
1.3.6.1.4.1.3833.1.2.2 port502SupportedProtocol00
1.3.6.1.4.1.3833.1.2.3 port502IpSecurity00
1.3.6.1.4.1.3833.1.2.4 port502MaxConn00
1.3.6.1.4.1.3833.1.2.5 port502LocalConn00
1.3.6.1.4.1.3833.1.2.6 port502RemConn00
1.3.6.1.4.1.3833.1.2.7 port502IpSecurityTable13
1.3.6.1.4.1.3833.1.2.8 port502ConnTable110
1.3.6.1.4.1.3833.1.2.9 port502MsgIn00
1.3.6.1.4.1.3833.1.2.10 port502MsgOut00
1.3.6.1.4.1.3833.1.2.11 port502MsgOutErr00
1.3.6.1.4.1.3833.1.2.12 port502AddStackStat00