The fastest rate at which remote publications can be sent for this variable [milliseconds].
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.4.10.1.7
The fastest rate at which remote publications can be sent for this variable [milliseconds].
Identification
{1 3 6 1 4 1 3833 1 4 10 1 7}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: glbDataSubGroupId, glbDataSubNetId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.4.10.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
glbDataMinimumSeparation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The fastest rate at which remote publications can be sent for this variable [milliseconds]."
::= { glbDataSubEntry 7 }glbDataMinimumSeparation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fastest rate at which remote publications can be sent for this variable [milliseconds]."
::= { glbDataSubEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The fastest rate at which remote publications can be sent for this variable [milliseconds].
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: glbDataMinimumSeparation
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"glbDataMinimumSeparation",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The fastest rate at which remote publications can be sent for this variable [milliseconds].\"",
"::=",
"{",
"glbDataSubEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The fastest rate at which remote publications can be sent for this variable [milliseconds]."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Status in source: current.
Names: glbDataMinimumSeparation
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"glbDataMinimumSeparation",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The fastest rate at which remote publications can be sent for this variable [milliseconds].\"",
"::=",
"{",
"glbDataSubEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The fastest rate at which remote publications can be sent for this variable [milliseconds]."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'SNMPv2-TC': ['PhysAddress', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Counter32']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE_V03.01.mib — M580 support packageRegistration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.4.10.1.1 | glbDataSubSourceAddress | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.2 | glbDataSubHostId | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.3 | glbDataSubNetId | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.4 | glbDataSubGroupId | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.5 | glbDataSubCnt | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.6 | glbDataSubErrCnt | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.8 | glbDataHealth | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.9 | glbDataHealthTimeOut | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.4.10.1.10 | glbDataLastRecErr | 0 | 0 |