The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers .
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.7.12
The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers .
Identification
{1 3 6 1 4 1 3833 1 7 12}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.3833.1.7.12.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
profileTrapTableEntriesMax OBJECT-TYPE
SYNTAX INTEGER (1 .. 2)
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum numbers of entries in the Trap Table.
This entry equals the number of possible remote Managers ."
::= { equipmentProfile 12 }profileTrapTableEntriesMax OBJECT-TYPE
SYNTAX Integer32 (1 .. 2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum numbers of entries in the Trap Table.
This entry equals the number of possible remote Managers ."
::= { equipmentProfile 12 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers .
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: optional.
Names: profileTrapTableEntriesMax
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"profileTrapTableEntriesMax",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"1",
".",
".",
"2",
")",
"ACCESS",
"read-only",
"STATUS",
"optional",
"DESCRIPTION",
"\"The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers .\"",
"::=",
"{",
"equipmentProfile",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
1,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"optional"
],
[
"DESCRIPTION",
"The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers ."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Status in source: current.
Names: profileTrapTableEntriesMax
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"profileTrapTableEntriesMax",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"2",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers .\"",
"::=",
"{",
"equipmentProfile",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The maximum numbers of entries in the Trap Table. This entry equals the number of possible remote Managers ."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'SNMPv2-TC': ['PhysAddress', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Counter32']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE_V03.01.mib — M580 support packageRegistration