The Community Name configured for the traps (local configuration).
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.7.13.1.1
The Community Name configured for the traps (local configuration).
Identification
{1 3 6 1 4 1 3833 1 7 13 1 1}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In TFPRIVATE-MIB, the row index remoteIpAddress is declared as IpAddress. The IPv4 address is encoded as four numeric subidentifiers, one for each address octet. For example, a row with address 192.0.2.10 has the instance .1.3.6.1.4.1.3833.1.7.13.1.1.192.0.2.10. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.7.13.1.1
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
trapCommunityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Community Name configured for the traps (local configuration)."
::= { profileTrapEntry 1 }trapCommunityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Community Name configured for the traps (local configuration)."
::= { profileTrapEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The Community Name configured for the traps (local configuration).
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: trapCommunityName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"trapCommunityName",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"1",
".",
".",
"16",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The Community Name configured for the traps (local configuration).\"",
"::=",
"{",
"profileTrapEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
1,
16
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The Community Name configured for the traps (local configuration)."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'SNMPv2-TC': ['PhysAddress', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Counter32']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE_V03.01.mib — M580 support packageRelated source files and packages:
Status in source: mandatory.
Names: trapCommunityName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"trapCommunityName",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"1",
".",
".",
"16",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The Community Name configured for the traps (local configuration).\"",
"::=",
"{",
"profileTrapEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
1,
16
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The Community Name configured for the traps (local configuration)."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRegistration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.7.13.1.2 | remoteIpAddress | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.3 | authenticationTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.4 | port502Trap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.5 | ioScanningTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.6 | globalDataTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.7 | webTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.8 | addressServerTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.9 | profileTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.10 | timeManagementTrap | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.7.13.1.11 | emailTrap | 0 | 0 |