OID reference

ntpServerChange

1.3.6.1.4.1.3833.1.8.1.0.8

Description

This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.8.1.0 (ntpV2)
Node code
8
Node name
ntpServerChange
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.3833.1.8.1.0.8
URN notation
urn:oid:1.3.6.1.4.1.3833.1.8.1.0.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 8 1 0 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) timeManagement(8) ntp(1) ntpV2(0) ntpServerChange(8)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/8/1/0/8
  • /ISO/Identified-Organization/6/1/4/1/3833/1/8/1/0/8
  • /ISO/3/6/1/4/1/3833/1/8/1/0/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/timeManagement/ntp/ntpV2/ntpServerChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/timeManagement/ntp/ntpV2/ntpServerChange
  • Additional combinations skipped.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

ntpServerChange · current

ntpServerChange NOTIFICATION-TYPE
	OBJECTS { ntpLnkSrvStatus, ntpSrvAddr }
	STATUS	current
    DESCRIPTION "This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa."
    ::= { ntpV2 8 }

ntpServerChange · unspecified

ntpServerChange TRAP-TYPE
    ENTERPRISE  ntp
    VARIABLES   { ntpLnkSrvStatus, ntpSrvAddr }
    DESCRIPTION "This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa."
    ::= 8

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa.

Sources for this description

Schneider Electric Transparent Factory official MIB

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB2 records · 2 sources

Description 1

ntpServerChange · currentSchneider Electric Transparent Factory official MIB1 source

Status in source: current.

Names: ntpServerChange

Technical details
{
  "smi_kind": "NOTIFICATION-TYPE",
  "definition": [
    "ntpServerChange",
    "NOTIFICATION-TYPE",
    "OBJECTS",
    "{",
    "ntpLnkSrvStatus",
    ",",
    "ntpSrvAddr",
    "}",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa.\"",
    "::=",
    "{",
    "ntpV2",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "Objects",
      [
        "ntpLnkSrvStatus",
        "ntpSrvAddr"
      ]
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa."
    ],
    null
  ]
}
ntpServerChange · unspecifiedSchneider Electric Transparent Factory official MIB1 source

Status in source: unspecified.

Names: ntpServerChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "ntpServerChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "ntp",
    "VARIABLES",
    "{",
    "ntpLnkSrvStatus",
    ",",
    "ntpSrvAddr",
    "}",
    "DESCRIPTION",
    "\"This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa.\"",
    "::=",
    "8"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "ntp"
      ]
    ],
    [
      "VarTypes",
      [
        "ntpLnkSrvStatus",
        "ntpSrvAddr"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap is sent if the NTP component switches from the Primary NTP Server to the Standby NTP Server or vice versa."
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (4)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.8.1.0.7 ntpStatusChange00
1.3.6.1.4.1.3833.1.8.1.0.9 ntpLnkSrvStatusChange00
1.3.6.1.4.1.3833.1.8.1.0.10 ntpLeapSecond00
1.3.6.1.4.1.3833.1.8.1.0.11 ntpDSTChange00