This table contains the properties for each smoke sensor
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3854.3.5.14
This table contains the properties for each smoke sensor
Identification
{1 3 6 1 4 1 3854 3 5 14}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
smokeTable OBJECT-TYPE
SYNTAX SEQUENCE OF SmokeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the properties for each smoke sensor"
::= { sensors 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This table contains the properties for each smoke sensor
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: smokeTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"smokeTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"SmokeEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This table contains the properties for each smoke sensor\"",
"::=",
"{",
"sensors",
"14",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"SmokeEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This table contains the properties for each smoke sensor"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SPAGENT-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'Opaque'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SPAGENT-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'Opaque'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3854.3.5.14.1 | smokeEntry | 12 | 12 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3854.3.5.1 | commonTable | 1 | 32 | |
| 1.3.6.1.4.1.3854.3.5.2 | temperatureTable | 1 | 39 | |
| 1.3.6.1.4.1.3854.3.5.3 | humidityTable | 1 | 37 | |
| 1.3.6.1.4.1.3854.3.5.4 | drycontactTable | 1 | 23 | |
| 1.3.6.1.4.1.3854.3.5.5 | current4to20mATable | 1 | 41 | |
| 1.3.6.1.4.1.3854.3.5.6 | dcVoltageTable | 1 | 42 | |
| 1.3.6.1.4.1.3854.3.5.7 | airflowTable | 1 | 35 | |
| 1.3.6.1.4.1.3854.3.5.8 | motionTable | 1 | 13 | |
| 1.3.6.1.4.1.3854.3.5.9 | waterTable | 1 | 13 | |
| 1.3.6.1.4.1.3854.3.5.10 | securityTable | 1 | 13 | |
| 1.3.6.1.4.1.3854.3.5.11 | sirenTable | 1 | 16 | |
| 1.3.6.1.4.1.3854.3.5.12 | relayTable | 1 | 17 | |
| 1.3.6.1.4.1.3854.3.5.13 | acVoltageTable | 1 | 13 | |
| 1.3.6.1.4.1.3854.3.5.21 | waterRopeTable | 1 | 19 | |
| 1.3.6.1.4.1.3854.3.5.22 | powerTable | 1 | 38 | |
| 1.3.6.1.4.1.3854.3.5.24 | fuelTable | 1 | 36 | |
| 1.3.6.1.4.1.3854.3.5.26 | tankSenderTable | 1 | 34 | |
| 1.3.6.1.4.1.3854.3.5.27 | doorTable | 1 | 10 | |
| 1.3.6.1.4.1.3854.3.5.28 | temperatureArrayTable | 1 | 39 | |
| 1.3.6.1.4.1.3854.3.5.29 | towerLEDTable | 1 | 13 | |
| 1.3.6.1.4.1.3854.3.5.31 | enumTable | 1 | 42 |