Description 1
Voltage maximum
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.38783.2.3.2
Voltage maximum
Identification
{1 3 6 1 4 1 38783 2 3 2}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 0 | disabled | 2 |
| 1 | enabled | 2 |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.38783.2.3.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
voltageMax OBJECT-TYPE
SYNTAX INTEGER (0..4000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Voltage maximum"
::= { analogInput 2 }filterMACEnable1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAC filter 1 Enable ENABLED/DISABLED"
::= { macFilter 2 }analog OBJECT IDENTIFIER ::= { monitorNcontrol 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Voltage maximum
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
MAC filter 1 Enable ENABLED/DISABLED
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: voltageMax
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"voltageMax",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"4000",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Voltage maximum\"",
"::=",
"{",
"analogInput",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
4000
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Voltage maximum"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW111-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download TERACOM-TCW111-MIBRelated source files and packages:
Status in source: mandatory.
Names: filterMACEnable1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"filterMACEnable1",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"disabled",
"(",
"0",
")",
",",
"enabled",
"(",
"1",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"MAC filter 1 Enable ENABLED/DISABLED\"",
"::=",
"{",
"macFilter",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"disabled",
0
],
[
"enabled",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"MAC filter 1 Enable ENABLED/DISABLED"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW121-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Status in source: unspecified.
Names: analog
{
"smi_kind": "OBJECT IDENTIFIER",
"definition": [
"analog",
"OBJECT",
"IDENTIFIER",
"::=",
"{",
"monitorNcontrol",
"2",
"}"
]
}Vendor MIB copy from the LibreNMS archive.
Module: TERACOM-TCW220-MIB
See published definition above
{'SNMPv2-TC': ['DateAndTime', 'MacAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.38783.2.3.2.1 | voltage1Int | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.2.2 | voltage2Int | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.2.3 | analogAlarm | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.38783.2.3.1 | sensors, filterMACAddress1, voltageMin | 8 | 56 | |
| 1.3.6.1.4.1.38783.2.3.3 | digital, filterMACAddress2, voltageHyst | 3 | 5 | |
| 1.3.6.1.4.1.38783.2.3.4 | relays, filterMACEnable2, voltageAction | 2 | 6 | |
| 1.3.6.1.4.1.38783.2.3.5 | configurationSaved, filterMACAddress3, voltageRange | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.6 | restartDevice, filterMACEnable3 | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.7 | temperatureUnit | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.8 | hardwareErr | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.9 | pressureUnit | 0 | 0 | |
| 1.3.6.1.4.1.38783.2.3.11 | virtual | 5 | 9 |