Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zxAnXdsl2LConfProfRaDsNrmsDs",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"310",
")",
"UNITS",
[
"literal",
"22302e3120644222"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The Downstream Down-Shift Noise Margin value, to be used when zxAnXdsl2LConfProfRaModeDs is set to dynamicRa. If the downstream noise margin is below this value and stays below that for more than the time specified by the zxAnXdsl2LConfProfRaDsTimeDs, the xTU-R shall attempt to decrease the downstream net data rate. The Downstream Down-shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB).\"",
"REFERENCE",
"\"ITU-T G.997.1, paragraph #7.3.1.4.7\"",
"DEFVAL",
"{",
"10",
"}",
"::=",
"{",
"zxAnXdsl2BaseConfProfEntry",
"25",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
310
]
]
]
],
[
"UNITS",
"0.1 dB"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The Downstream Down-Shift Noise Margin value, to be used when zxAnXdsl2LConfProfRaModeDs is set to dynamicRa. If the downstream noise margin is below this value and stays below that for more than the time specified by the zxAnXdsl2LConfProfRaDsTimeDs, the xTU-R shall attempt to decrease the downstream net data rate. The Downstream Down-shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB)."
],
[
"REFERENCE",
"ITU-T G.997.1, paragraph #7.3.1.4.7"
],
null,
null,
[
"DEFVAL",
10
]
]
}