Status in source: current.
Names: zxAnEventSyslogSeverity
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zxAnEventSyslogSeverity",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"7",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The syslog message severity, The priority value of PRI is calculated by first multiplying the Facility number by 8 and then adding the numerical value of the Severity. Numerical Code Severity 0 Emergency: system is unusable 1 Alert: action must be taken immediately 2 Critical: critical conditions 3 Error: error conditions 4 Warning: warning conditions 5 Notice: normal but significant condition 6 Informational: informational messages 7 Debug: debug-level messages More information, please refer to rfc3164. \"",
"::=",
"{",
"zxAnEventSyslogGlobalObjects",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
7
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The syslog message severity, The priority value of PRI is calculated by first multiplying the Facility number by 8 and then adding the numerical value of the Severity. Numerical Code Severity 0 Emergency: system is unusable 1 Alert: action must be taken immediately 2 Critical: critical conditions 3 Error: error conditions 4 Warning: warning conditions 5 Notice: normal but significant condition 6 Informational: informational messages 7 Debug: debug-level messages More information, please refer to rfc3164."
],
null,
null,
null,
null
]
}