"smi_kind": "OBJECT-TYPE",
"definition": [
"zxAnOtdrEnvApdTempLowThresh",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"55",
".",
".",
"-",
"20",
")",
"UNITS",
[
"literal",
"2243656e7469677261646522"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The low threshold of the APD temperature, the zxAnOtdrEnvApdLowTempAlm trap should be generated when zxAnOtdrEnvApdCurrentTemp is lower than it. Otherwise, zxAnOtdrEnvApdLowTempClr trap should be generated when zxAnOtdrEnvApdCurrentTemp higher than it.\"",
"DEFVAL",
"{",
"-",
"20",
"}",
"::=",
"{",
"zxAnOtdrEnvApdGlobalObjects",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-55,
-20
]
]
]
],
[
"UNITS",
"Centigrade"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The low threshold of the APD temperature, the zxAnOtdrEnvApdLowTempAlm trap should be generated when zxAnOtdrEnvApdCurrentTemp is lower than it. Otherwise, zxAnOtdrEnvApdLowTempClr trap should be generated when zxAnOtdrEnvApdCurrentTemp higher than it."
],
null,
null,
null,
[
"DEFVAL",
-20
]
]
}