The delay(minute) reopenning the interface after it was shut down. default 10 minute
Sources for this description
ZTE MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3902.3.102.15.1
The delay(minute) reopenning the interface after it was shut down. default 10 minute
Identification
{1 3 6 1 4 1 3902 3 102 15 1}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.3902.3.102.15.1.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
loopdetectReopenTime OBJECT-TYPE
SYNTAX Integer32 (1..16777216)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay(minute) reopenning the interface after it was shut down.
default 10 minute"
::= { loopdetect 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The delay(minute) reopenning the interface after it was shut down. default 10 minute
ZTE MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: loopdetectReopenTime
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"loopdetectReopenTime",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"16777216",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The delay(minute) reopenning the interface after it was shut down. default 10 minute\"",
"::=",
"{",
"loopdetect",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
16777216
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The delay(minute) reopenning the interface after it was shut down. default 10 minute"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. ZTE support.
Module: ZXR10-SWITCH-MIB
See published definition above
{'SNMPv2-TC': ['MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'experimental', 'Integer32', 'Unsigned32', 'Counter32', 'enterprises'], 'RFC1155-SMI': ['mgmt', 'NetworkAddress', 'IpAddress', 'Counter', 'Gauge'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages: