This value indicates sequence number of the trap last sent.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3942.1.1.3.8
This value indicates sequence number of the trap last sent.
Identification
{1 3 6 1 4 1 3942 1 1 3 8}
A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.
Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.
Published counter width: 32 bits. SMIv2: Counter32 · Counter64
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sysTrapSequence OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value indicates sequence number of the trap last sent."
::= { aquasystemMIB 8 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This value indicates sequence number of the trap last sent.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sysTrapSequence
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sysTrapSequence",
"OBJECT-TYPE",
"SYNTAX",
"Counter32",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"This value indicates sequence number of the trap last sent.\"",
"::=",
"{",
"aquasystemMIB",
"8",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter32"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This value indicates sequence number of the trap last sent."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: AQUASYSTEM-MIB
See published definition above
{'IF-MIB': ['ifEntry'], 'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'IpAddress'], 'INFINET-MIB': ['wanflex'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3942.1.1.3.1 | sysGPSXY | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.2 | sysFastRoute | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.3 | sysICMPLimit | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.4 | sysSendRedirects | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.5 | sysDropRedirects | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.6 | sysCpu | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.7 | sysTemperature | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.9 | sysSerialNumber | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.10 | sysRestartTimer | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.11 | sysSerialNumberStr | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.12 | sysNote | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.13 | sysLastRebootReason | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.14 | sysSoftwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.15 | sysModel | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.16 | sysFirmwareID | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.17 | sysBuildDate | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.18 | sysBuildTime | 0 | 0 | |
| 1.3.6.1.4.1.3942.1.1.3.20 | sysIf | 1 | 6 | |
| 1.3.6.1.4.1.3942.1.1.3.21 | sysMem | 5 | 5 | |
| 1.3.6.1.4.1.3942.1.1.3.22 | sysQueue | 1 | 7 | |
| 1.3.6.1.4.1.3942.1.1.3.23 | sysMgmt | 4 | 22 | |
| 1.3.6.1.4.1.3942.1.1.3.100 | aquasystemMIBConformance | 2 | 4 |