For each stack unit there is an entry describing it in this table
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3955.1000.201.53.4
For each stack unit there is an entry describing it in this table
Identification
{1 3 6 1 4 1 3955 1000 201 53 4}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlPhdStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each stack unit there is an entry describing it in this table"
::= { rlPhysicalDescription 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
For each stack unit there is an entry describing it in this table
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlPhdStackTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlPhdStackTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"RlPhdStackEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"For each stack unit there is an entry describing it in this table\"",
"::=",
"{",
"rlPhysicalDescription",
"4",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"RlPhdStackEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"For each stack unit there is an entry describing it in this table"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: LINKSYS-Physicaldescription-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE'], 'LINKSYS-MIB': ['rnd', 'rndNotifications'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'LINKSYS-HWENVIROMENT': ['RlEnvMonState'], 'LINKSYS-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3955.1000.201.53.4.1 | rlPhdStackEntry | 7 | 7 |