This is Expanded IO32 Modules connecting status. Range: 0: disconnected,1: connected
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.39604.1.1.1.1.6.1.6
This is Expanded IO32 Modules connecting status. Range: 0: disconnected,1: connected
Identification
{1 3 6 1 4 1 39604 1 1 1 1 6 1 6}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.39604.1.1.1.1.6.1.6.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
axmIO32Status OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION
"This is Expanded IO32 Modules connecting status.
Range: 0: disconnected,1: connected"
::= { expandedIOModulesConnectStatus 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This is Expanded IO32 Modules connecting status. Range: 0: disconnected,1: connected
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: axmIO32Status
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"axmIO32Status",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This is Expanded IO32 Modules connecting status. Range: 0: disconnected,1: connected\"",
"::=",
"{",
"expandedIOModulesConnectStatus",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This is Expanded IO32 Modules connecting status. Range: 0: disconnected,1: connected"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ACCUENERGY-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'RFC1155-SMI': ['enterprises', 'Integer32', 'Counter32', 'TimeTicks']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.39604.1.1.1.1.6.1.1 | axmIO11Status | 0 | 0 | |
| 1.3.6.1.4.1.39604.1.1.1.1.6.1.2 | axmIO12Status | 0 | 0 | |
| 1.3.6.1.4.1.39604.1.1.1.1.6.1.3 | axmIO21Status | 0 | 0 | |
| 1.3.6.1.4.1.39604.1.1.1.1.6.1.4 | axmIO22Status | 0 | 0 | |
| 1.3.6.1.4.1.39604.1.1.1.1.6.1.5 | axmIO31Status | 0 | 0 |