The temperature alarm. normal(0), low temperature alarm(1), high temperature alarm(2).
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.40297.1.2.1.1.2
The temperature alarm. normal(0), low temperature alarm(1), high temperature alarm(2).
Identification
{1 3 6 1 4 1 40297 1 2 1 1 2}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.40297.1.2.1.1.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rptTemperatureAlarm OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The temperature alarm.
normal(0), low temperature alarm(1), high temperature alarm(2)."
DEFVAL { 0 }
-- 1.3.6.1.4.1.40297.1.2.1.1.2
::= { rptAlarmInfo 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The temperature alarm. normal(0), low temperature alarm(1), high temperature alarm(2).
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: rptTemperatureAlarm
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rptTemperatureAlarm",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"2",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The temperature alarm. normal(0), low temperature alarm(1), high temperature alarm(2).\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"rptAlarmInfo",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The temperature alarm. normal(0), low temperature alarm(1), high temperature alarm(2)."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: HYTERA-REPEATER-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['private', 'enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.40297.1.2.1.1.1 | rptVoltageAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.3 | rptFanAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.4 | rptForwardAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.5 | rptReflectedAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.6 | rptVswrAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.7 | rptTxPllAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.8 | rptRxPllAlarm | 0 | 0 | |
| 1.3.6.1.4.1.40297.1.2.1.1.9 | rptBatteryVoltageAlarm | 0 | 0 |