erd2do2state — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
DO2 states and modes. If DO2 in thermostat or gidrolock mode, then autoLOW and autoHIGH states are used
{1 3 6 1 4 1 40418 2 2 2 3}
DO2 states and modes. If DO2 in thermostat or gidrolock mode, then autoLOW and autoHIGH states are used
qwerty
Status in source: current.
Names: erd2do2state
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"erd2do2state",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"manualLOW",
"(",
"0",
")",
",",
"manualHIGH",
"(",
"1",
")",
",",
"setManualMode",
"(",
"2",
")",
",",
"setTermostatMode",
"(",
"3",
")",
",",
"switch",
"(",
"4",
")",
",",
"autoLOW",
"(",
"5",
")",
",",
"autoHIGH",
"(",
"6",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"DO2 states and modes. If DO2 in thermostat or gidrolock mode, then autoLOW and autoHIGH states are used\"",
"::=",
"{",
"erd2outputs",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"manualLOW",
0
],
[
"manualHIGH",
1
],
[
"setManualMode",
2
],
[
"setTermostatMode",
3
],
[
"switch",
4
],
[
"autoLOW",
5
],
[
"autoHIGH",
6
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"DO2 states and modes. If DO2 in thermostat or gidrolock mode, then autoLOW and autoHIGH states are used"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SNR-ERD-2-MIB
erd2do2state OBJECT-TYPE
SYNTAX INTEGER
{
manualLOW (0),
manualHIGH (1),
setManualMode (2),
setTermostatMode(3),
switch (4),
autoLOW (5),
autoHIGH (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "DO2 states and modes.
If DO2 in thermostat or gidrolock mode, then autoLOW and autoHIGH states are used"
::= { erd2outputs 3 }{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:26.013162+00:00.
Status in source: current.
Names: remoteControlContact8
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"remoteControlContact8",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"termostatSetON",
"(",
"3",
")",
",",
"switch",
"(",
"4",
")",
",",
"manualSetON",
"(",
"2",
")",
",",
"manOFF",
"(",
"1",
")",
",",
"manON",
"(",
"0",
")",
",",
"autoOFF",
"(",
"6",
")",
",",
"autoON",
"(",
"5",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"qwerty\"",
"::=",
"{",
"resetsSet",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"termostatSetON",
3
],
[
"switch",
4
],
[
"manualSetON",
2
],
[
"manOFF",
1
],
[
"manON",
0
],
[
"autoOFF",
6
],
[
"autoON",
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"qwerty"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SNR-ERD-DUST
remoteControlContact8 OBJECT-TYPE
SYNTAX INTEGER
{
termostatSetON (3),
switch (4),
manualSetON (2),
manOFF (1),
manON (0),
autoOFF (6),
autoON (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "qwerty"
::= { resetsSet 3 }{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP']}Downloaded: 2026-10-24T02:14:26.008162+00:00.
Status in source: current.
Names: remoteControlContactDO2
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"remoteControlContactDO2",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"termostatSetON",
"(",
"3",
")",
",",
"switch",
"(",
"4",
")",
",",
"manualSetON",
"(",
"2",
")",
",",
"manOFF",
"(",
"1",
")",
",",
"manON",
"(",
"0",
")",
",",
"autoOFF",
"(",
"6",
")",
",",
"autoON",
"(",
"5",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"qwerty\"",
"::=",
"{",
"resetsSet",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"termostatSetON",
3
],
[
"switch",
4
],
[
"manualSetON",
2
],
[
"manOFF",
1
],
[
"manON",
0
],
[
"autoOFF",
6
],
[
"autoON",
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"qwerty"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SNR-ERD-2
remoteControlContactDO2 OBJECT-TYPE
SYNTAX INTEGER
{
termostatSetON (3),
switch (4),
manualSetON (2),
manOFF (1),
manON (0),
autoOFF (6),
autoON (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "qwerty"
::= { resetsSet 3 }{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP']}Downloaded: 2026-10-24T02:14:26.015162+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.40418.2.2.2.1 | resetSmartContact6, erd2do1state, resetSmartContactDO1 | 0 | 0 | |
| 1.3.6.1.4.1.40418.2.2.2.2 | numberOfResetDevice, erd2do1resetCounter, numberOfResetPositives | 0 | 0 |