The measured battery capacity expressed in 10 watt*minutes/count as determined by the last battery test cycle.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4115.1.3.3.1.3.5.6
The measured battery capacity expressed in 10 watt*minutes/count as determined by the last battery test cycle.
Identification
{1 3 6 1 4 1 4115 1 3 3 1 3 5 6}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4115.1.3.3.1.3.5.6.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
arrisMtaDevPwrSupplyTestedBatCapacity OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured battery capacity expressed in 10 watt*minutes/count as determined
by the last battery test cycle."
::= { arrisMtaDevPwrSupplyStats 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The measured battery capacity expressed in 10 watt*minutes/count as determined by the last battery test cycle.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: arrisMtaDevPwrSupplyTestedBatCapacity
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"arrisMtaDevPwrSupplyTestedBatCapacity",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The measured battery capacity expressed in 10 watt*minutes/count as determined by the last battery test cycle.\"",
"::=",
"{",
"arrisMtaDevPwrSupplyStats",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The measured battery capacity expressed in 10 watt*minutes/count as determined by the last battery test cycle."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ARRIS-MTA-DEVICE-MIB
See published definition above
{'ARRIS-MIB': ['arrisProdIdCM'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION', 'PhysAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.3 | arrisMtaDevBatteryStatusTable | 1 | 7 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.4 | arrisMtaDevPwrSupplyBatteryTestTime | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.5 | arrisMtaDevPwrSupplyRatedBatCapacity | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.7 | arrisMtaDevPwrSupplyBatStateOfCharge | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.8 | arrisMtaDevPwrSupplyReadBatteryPwr | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.9 | arrisMtaDevPwrSupplySecondsOnBattery | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.10 | arrisMtaDevPwrSupplyBatRatedMinutes | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.11 | arrisMtaDevPwrSupplyBatAvailableMinutes | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.12 | arrisMtaDevPwrSupplySecondsOnBattery2 | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.13 | arrisMtaDevPwrSupplyBatRatedMinutes2 | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.14 | arrisMtaDevPwrSupplyBatAvailableMinutes2 | 0 | 0 | |
| 1.3.6.1.4.1.4115.1.3.3.1.3.5.15 | arrisMtaDevPwrSupplyTelemetryValues | 0 | 0 |