Description 1
probe monitoring this input range. 0 indicates no probe provided.
Sources for this description
CircitorMIBdepot
Circitor
Parsed from DMTF-SYSTEMS-MIB.mib · DMTF-SYSTEMS-MIB
Source file: Download DMTF-SYSTEMS-MIB.mib
OID reference
1.3.6.1.4.1.412.2.4.16.1.13
Index into the Voltage Probe table identifying the voltage probe monitoring this input range. 0 indicates no probe provided.
Identification
{1 3 6 1 4 1 412 2 4 16 1 13}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
range2VoltageProbeIndexAtt13 OBJECT-TYPE
SYNTAX DmiInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index into the Voltage Probe table identifying the voltage
probe monitoring this input range. 0 indicates no probe provided."
REFERENCE "'DMTF|Power Supply|002' 13"
::= { dMTFPowerSupplyEntry 13 }a17Range2VoltageProbeIndex OBJECT-TYPE
SYNTAX DmiInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index into the Voltage Probe table identifying the voltage
probemonitoring this input range. 0 indicates no probe provided."
::= {ePowerSupply 13}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
CircitorMIBdepot
Parsed from DMTF-SYSTEMS-MIB.mib · DMTF-SYSTEMS-MIB
Source file: Download DMTF-SYSTEMS-MIB.mib
Description 2
Index into the Voltage Probe table identifying the voltage probemonitoring this input range. 0 indicates no probe provided.
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: range2VoltageProbeIndexAtt13
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"range2VoltageProbeIndexAtt13",
"OBJECT-TYPE",
"SYNTAX",
"DmiInteger",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Index into the Voltage Probe table identifying the voltage probe monitoring this input range. 0 indicates no probe provided.\"",
"REFERENCE",
"\"'DMTF|Power Supply|002' 13\"",
"::=",
"{",
"dMTFPowerSupplyEntry",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DmiInteger"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Index into the Voltage Probe table identifying the voltage probe monitoring this input range. 0 indicates no probe provided."
],
[
"REFERENCE",
"'DMTF|Power Supply|002' 13"
],
null,
null,
null
]
}Module: BASEBRDD_MIB-MIB
See published definition above
{'DMTF-DMI': ['Dmi_Date', 'Dmi_Integer64', 'dmiEventDateTime', 'dmiCompId', 'dmiEventSeverity', 'dmiEventStateKey', 'dmiEventAssociatedGroup', 'dmiEventSystem', 'dmiEventSubSystem'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['Counter', 'Gauge', 'DisplayString'], 'HOST-RESOURCES-MIB': ['InternationalDisplayString']}Module: BASEBRDD_MIB-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['Counter', 'Gauge', 'DisplayString'], 'DMTF-DMI-MIB': ['Dmi_Date', 'Dmi_Integer64', 'dmiEventDateTime', 'dmiCompId', 'dmiEventSeverity', 'dmiEventStateKey', 'dmiEventAssociatedGroup', 'dmiEventSystem', 'dmiEventSubSystem'], 'HOST-RESOURCES-MIB': ['InternationalDisplayString']}Module: BASEBRDD_MIB-MIB
{'DMTF-DMI': ['Dmi_Date', 'Dmi_Integer64', 'dmiEventDateTime', 'dmiCompId', 'dmiEventSeverity', 'dmiEventStateKey', 'dmiEventAssociatedGroup', 'dmiEventSystem', 'dmiEventSubSystem'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['Counter', 'Gauge', 'DisplayString'], 'HOST-RESOURCES-MIB': ['InternationalDisplayString']}Status in source: mandatory.
Names: range2VoltageProbeIndexAtt13
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"range2VoltageProbeIndexAtt13",
"OBJECT-TYPE",
"SYNTAX",
"DmiInteger",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Index into the Voltage Probe table identifying the voltage probe monitoring this input range. 0 indicates no probe provided.\"",
"REFERENCE",
"\"'DMTF|Power Supply|002' 13\"",
"::=",
"{",
"dMTFPowerSupplyEntry",
"13",
"}"
],
"syntax_tree": [
[
"row",
"DmiInteger"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Index into the Voltage Probe table identifying the voltage probe monitoring this input range. 0 indicates no probe provided."
],
[
"REFERENCE",
"'DMTF|Power Supply|002' 13"
],
null,
null,
null
]
}Module: BASEBRDD-MIB-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-SMI': ['Counter64'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'DMTF-DMI-MIB': ['DmiDate', 'DmiInteger64', 'dmiEventDateTime', 'dmiCompId', 'dmiEventSeverity', 'dmiEventStateKey', 'dmiEventAssociatedGroup', 'dmiEventSystem', 'dmiEventSubSystem'], 'HOST-RESOURCES-MIB': ['InternationalDisplayString']}Status in source: mandatory.
Names: a17Range2VoltageProbeIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"a17Range2VoltageProbeIndex",
"OBJECT-TYPE",
"SYNTAX",
"DmiInteger",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Index into the Voltage Probe table identifying the voltage probemonitoring this input range. 0 indicates no probe provided.\"",
"::=",
"{",
"ePowerSupply",
"13",
"}"
],
"syntax_tree": [
[
"row",
"DmiInteger"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Index into the Voltage Probe table identifying the voltage probemonitoring this input range. 0 indicates no probe provided."
],
null,
null,
null,
null
]
}Module: INTELCORPORATIONBASEBOARDMAPPER-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'SNMPv2-SMI': ['NOTIFICATION-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises'], 'RFC1213-MIB': ['DisplayString']}Historical records
range2VoltageProbeIndex OBJECT-TYPE
SYNTAX DmiInteger
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Index into the Voltage Probe table identifying the voltage
probe monitoring this input range. 0 indicates no probe provided."
REFERENCE "'DMTF|Power Supply|002' 13"
::= { dmtfPowerSupplyEntry 13 }
range2VoltageProbeIndex OBJECT-TYPE
SYNTAX DmiInteger
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Index into the Voltage Probe table identifying the voltage
probe monitoring this input range. 0 indicates no probe provided."
REFERENCE "'DMTF|Power Supply|002' 13"
::= { dmtfPowerSupplyEntry 13 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.412.2.4.16.1.0 | dMTFPowerSupplyState, dmtfPowerSupplyState | 0 | 0 | " REFERENCE "'DMTF|Power Supply|002' 0 |
| 1.3.6.1.4.1.412.2.4.16.1.1 | powerSupplyIndexAtt1, a17PowerSupplyIndex, powerSupplyIndex | 0 | 0 | The index number of the current power supply. |
| 1.3.6.1.4.1.412.2.4.16.1.2 | fRUGroupIndexAtt2_1, a17FruGroupIndex, fRUGroupIndexAtt2-1, fRUGroupIndex | 0 | 0 | If this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' ind… |
| 1.3.6.1.4.1.412.2.4.16.1.3 | operationalGroupIndexAtt3_1, a17OperationalGroupIndex, operationalGroupIndexAtt3-1, operationalGroupIndex | 0 | 0 | The index into the Operational State table for this device. |
| 1.3.6.1.4.1.412.2.4.16.1.4 | powerUnitIndexAtt4, a17PowerUnitIndex, powerUnitIndex | 0 | 0 | This is the ID of the Power Unit (logical power supply) to which this Power Supply belongs. This value matches up with the Power… |
| 1.3.6.1.4.1.412.2.4.16.1.5 | powerSupplyTypeAtt5, powerSupplyType, a17PowerSupplyType | 0 | 0 | This attribute describes the type of Power Supply, e.g. Linear, Switching, Battery, etc. |
| 1.3.6.1.4.1.412.2.4.16.1.6 | inputVoltageCapabilityDescriptionAtt6, inputVoltageCapabilityDescription, a17InputVoltageCapabilityDescription | 0 | 0 | An expanded description of the Input Voltage Capability for this Power Supply. |
| 1.3.6.1.4.1.412.2.4.16.1.7 | range1InputVoltageLowAtt7, range1InputVoltageLow, a17Range1InputVoltageLow | 0 | 0 | The low voltage of Input Voltage Range 1 for this Power Supply, in millivolts. A value of 0x80000000 denotes 'unknown'. |
| 1.3.6.1.4.1.412.2.4.16.1.8 | range1InputVoltageHighAtt8, range1InputVoltageHigh, a17Range1InputVoltageHigh | 0 | 0 | The high voltage of Input Voltage Range 1 for this Power Supply, in millivolts. A value of 0x80000000 denotes 'unknown'. |
| 1.3.6.1.4.1.412.2.4.16.1.9 | range1VoltageProbeIndexAtt9, range1VoltageProbeIndex, a17Range1VoltageProbeIndex | 0 | 0 | Index into the Voltage Probe table identifying the voltage probe monitoring this input range. 0 indicates no probe provided. |
| 1.3.6.1.4.1.412.2.4.16.1.10 | range1ElectricalCurrentProbeIndexAtt10, range1ElectricalCurrentProbeIndex, a17Range1ElectricalCurrentProbeIndex | 0 | 0 | Index into the Elelctrical Current Probe table identifying the Electrical current probe monitoring this input range. 0 indicates… |
| 1.3.6.1.4.1.412.2.4.16.1.11 | range2InputVoltageLowAtt11, range2InputVoltageLow, a17Range2InputVoltageLow | 0 | 0 | The low voltage of Input Voltage Range 2 for this Power Supply, in millivolts. A value of 0x80000000 denotes 'unknown'. |
| 1.3.6.1.4.1.412.2.4.16.1.12 | range2InputVoltageHighAtt12, range2InputVoltageHigh, a17Range2InputVoltageHigh | 0 | 0 | The high voltage of Input Voltage Range 2 for this Power Supply, in millivolts. A value of 0x80000000 denotes 'unknown' |
| 1.3.6.1.4.1.412.2.4.16.1.14 | range2CurrentProbeIndexAtt14, range2CurrentProbeIndex, a17Range2CurrentProbeIndex | 0 | 0 | Index into the Current Probe table identifying the current probe monitoring this input range. 0 indicates no probe provided. |
| 1.3.6.1.4.1.412.2.4.16.1.15 | activeInputVoltageRangeAtt15, activeInputVoltageRange, a17ActiveInputVoltageRange | 0 | 0 | The value of this attribute indicates which input voltage range of this Power Supply is currently active. |
| 1.3.6.1.4.1.412.2.4.16.1.16 | inputVoltageRangeSwitchingAtt16, inputVoltageRangeSwitching, a17InputVoltageRangeSwitching | 0 | 0 | This attribute describes the kind of input voltage range switching that is implemented in this power supply. |
| 1.3.6.1.4.1.412.2.4.16.1.17 | range1InputFrequencyLowAtt17, range1InputFrequencyLow, a17Range1InputFrequencyLow | 0 | 0 | The frequency at the low end of this power supply's Input Frequency Range 1. A value of zero implies DC. A value of 0x80000000 d… |
| 1.3.6.1.4.1.412.2.4.16.1.18 | range1InputFrequencyHighAtt18, range1InputFrequencyHigh, a17Range1InputFrequencyHigh | 0 | 0 | The frequency at the high end of this power supply's Input Frequency Range 1. A value of zero implies DC. A value of 0x80000000 … |
| 1.3.6.1.4.1.412.2.4.16.1.19 | range2InputFrequencyLowAtt19, range2InputFrequencyLow, a17Range2InputFrequencyLow | 0 | 0 | The frequency at the low end of this power supply's Input Frequency Range 2. A value of zero implies DC. A value of 0x80000000 d… |
| 1.3.6.1.4.1.412.2.4.16.1.20 | range2InputFrequencyHighAtt20, range2InputFrequencyHigh, a17Range2InputFrequencyHigh | 0 | 0 | The frequency at the high end of this power supply's Input Frequency Range 2. A value of zero implies DC. A value of 0x80000000 … |
| 1.3.6.1.4.1.412.2.4.16.1.21 | totalOutputPowerAtt21, totalOutputPower, a17TotalOutputPower | 0 | 0 | This attribute value represents the total output power of this power supply in milliWatts. 0x80000000 denotes 'unknown' |