Basic capabilities of configuration management.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.4249.3.2.6
Basic capabilities of configuration management.
Identification
{1 3 6 1 4 1 4249 3 2 6}
The displayed source records contain one distinct definition. Compare its source records.
nateksConfigFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic capabilities of configuration management."
MODULE
MANDATORY-GROUPS { nateksConfigConfirmedGroup,
nateksConfigBackupGroup,
nateksConfigGroupsGroup
}
GROUP nateksConfigRWGroup
DESCRIPTION
"The configRW variable may be not accessible if implementation of
configuration management subsystem of a device can not serialize
configuration to a string of bytes.
The configRW variable may be read-only if writing device configuration
this way can not be supported.
The configRW variable may be not accessible if device configuration
size exceeds internal SNMP PDU size limitations of device's SNMP agent."
::= { nateksMIBCompliance 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Basic capabilities of configuration management.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: nateksConfigFullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"nateksConfigFullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"Basic capabilities of configuration management.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"nateksConfigConfirmedGroup",
",",
"nateksConfigBackupGroup",
",",
"nateksConfigGroupsGroup",
"}",
"GROUP",
"nateksConfigRWGroup",
"DESCRIPTION",
"\"The configRW variable may be not accessible if implementation of configuration management subsystem of a device can not serialize configuration to a string of bytes. The configRW variable may be read-only if writing device configuration this way can not be supported. The configRW variable may be not accessible if device configuration size exceeds internal SNMP PDU size limitations of device's SNMP agent.\"",
"::=",
"{",
"nateksMIBCompliance",
"6",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"Basic capabilities of configuration management."
],
null,
[
"ComplianceModules",
[
[
null,
[
"nateksConfigConfirmedGroup",
"nateksConfigBackupGroup",
"nateksConfigGroupsGroup",
"nateksConfigRWGroup"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: NATEKS-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Gauge32', 'Integer32', 'IpAddress', 'TimeTicks'], 'RFC1213-MIB': ['ifDescr'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: NATEKS-MIB
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Gauge32', 'Integer32', 'IpAddress', 'TimeTicks'], 'RFC1213-MIB': ['ifDescr'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4249.3.2.1 | nateksMinCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.2 | nateksBasicCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.3 | nateksConfigBasicCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.4 | nateksConfigConfirmedCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.5 | nateksConfigBackupCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.7 | nateksG826Compliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.8 | nateksIfAlarmCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.9 | nateksTLMCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.10 | nateksDSLLTUCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.11 | nateksDSLRegeneratorCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.12 | nateksIndicationCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.13 | nateksTemperatureCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.14 | nateksTimeCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.15 | nateksLocalPowerCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.16 | nateksTFTPManagementCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.17 | nateksMacFilterCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.18 | nateksSfpDDMGroupCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.19 | nateksDigitalIoCompliance | 0 | 0 | |
| 1.3.6.1.4.1.4249.3.2.20 | nateksStatResetCompliance | 0 | 0 |