testLoopUnidirectional
Line, Data, and V54 loops will be unidirectional
Local loop will be bidirectional
testLoopBidirectional
All loops will be bidirectional
OID reference
1.3.6.1.4.1.425.8.8.3.1.5
This object is the identifier of the current unit loop mode. The values mean: testLoopUnidirectional Line, Data, and V54 loops will be unidirectional Local loop will be bidirectional testLoopBidirectional All loops will be bidirectional
Identification
{1 3 6 1 4 1 425 8 8 3 1 5}
| Value | Name |
|---|---|
| 1 | testLoopOther |
| 2 | testLoopUnidirectional |
| 3 | testLoopBidirectional |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In INTERFACES-MIB, the row index consists of these components in order:
testNearIndex (INTEGER): one numeric subidentifier for the non-negative value.testFarIndex (INTEGER): one numeric subidentifier for the non-negative value.testTableIndex (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.425.8.8.3.1.5.<testNearIndex>.<testFarIndex>.<testTableIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.425.8.8.3.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Historical records
testLoopDirection OBJECT-TYPE
SYNTAX INTEGER
{
testLoopOther(1),
testLoopUnidirectional(2),
testLoopBidirectional(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is the identifier of the current unit loop mode. The values mean:
testLoopUnidirectional
Line, Data, and V54 loops will be unidirectional
Local loop will be bidirectional
testLoopBidirectional
All loops will be bidirectional"
::= { testTableEntry 5 }
testLoopDirection OBJECT-TYPE
SYNTAX INTEGER
{
testLoopOther(1),
testLoopUnidirectional(2),
testLoopBidirectional(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is the identifier of the current unit loop mode. The values mean:
testLoopUnidirectional
Line, Data, and V54 loops will be unidirectional
Local loop will be bidirectional
testLoopBidirectional
All loops will be bidirectional"
::= { testTableEntry 5 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.425.8.8.3.1.1 | testNearIndex | 0 | 0 | Selects the near device. |
| 1.3.6.1.4.1.425.8.8.3.1.2 | testFarIndex | 0 | 0 | Selects the far device. |
| 1.3.6.1.4.1.425.8.8.3.1.3 | testTableIndex | 0 | 0 | The index into the testTable, one entry for each interface. |
| 1.3.6.1.4.1.425.8.8.3.1.4 | testType | 0 | 0 | Identifies the test type for the interface. |
| 1.3.6.1.4.1.425.8.8.3.1.6 | testFarLLBFraming | 0 | 0 | This setting, for Far LLB tests on T1 lines, must match the far end unit loop code framing. |