OID reference

inletCfgVoltWarnPhase1

1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13

Description

The Warning Threshold of pahse1b2 current of inlet.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1 (pduPwrMonitoringInletCfgEntry)
Node code
13
Node names
  • inletCfgVoltWarnPhase1
  • inletCfgCurrWarnPhase1b2
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13
URN notation
urn:oid:1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 42610 1 4 4 1 6 1 3 1 13}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgVoltWarnPhase1(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringInlet(1) pduPwrMonitoringInletCfgTable(3) pduPwrMonitoringInletCfgEntry(1) inletCfgCurrWarnPhase1b2(13)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/42610/1/4/4/1/6/1/3/1/13
  • /ISO/Identified-Organization/6/1/4/1/42610/1/4/4/1/6/1/3/1/13
  • /ISO/3/6/1/4/1/42610/1/4/4/1/6/1/3/1/13
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprise/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprise/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprise/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprise/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprise/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprise/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprise/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprises/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprises/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprises/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprises/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprises/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprises/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • /iso/identified-organization/dod/internet/private/enterprises/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgVoltWarnPhase1
  • /iso/identified-organization/dod/internet/private/enterprises/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringInlet/pduPwrMonitoringInletCfgTable/pduPwrMonitoringInletCfgEntry/inletCfgCurrWarnPhase1b2
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Units
0.1A, 0.1V
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Units
0.1A
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Units
0.1V
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In SPSv1-MIB, the row index inletCfgIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13.<inletCfgIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

inletCfgCurrWarnPhase1b2 · mandatory

inletCfgCurrWarnPhase1b2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse1b2 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 13 }

inletCfgVoltWarnPhase1 · mandatory

inletCfgVoltWarnPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse1 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 13 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The Warning Threshold of pahse1b2 current of inlet.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

The Warning Threshold of pahse1 voltage of inlet.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

inletCfgCurrWarnPhase1b2 · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: inletCfgCurrWarnPhase1b2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "inletCfgCurrWarnPhase1b2",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "UNITS",
    [
      "literal",
      "22302e314122"
    ],
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The Warning Threshold of pahse1b2 current of inlet.\"",
    "::=",
    "{",
    "pduPwrMonitoringInletCfgEntry",
    "13",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    [
      "UNITS",
      "0.1A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The Warning Threshold of pahse1b2 current of inlet."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

inletCfgVoltWarnPhase1 · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: inletCfgVoltWarnPhase1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "inletCfgVoltWarnPhase1",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "UNITS",
    [
      "literal",
      "22302e315622"
    ],
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The Warning Threshold of pahse1 voltage of inlet.\"",
    "::=",
    "{",
    "pduPwrMonitoringInletCfgEntry",
    "13",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    [
      "UNITS",
      "0.1V"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The Warning Threshold of pahse1 voltage of inlet."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.42610)

salvador trullols rico

Siblings (29)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.1 inletCfgIndex00
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.2 inletCfgLoadCritical00
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.3 inletCfgLoadWarning00
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.4 inletCfgCurrCritPhase1, inletCfgCurrCritPhase1b100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.5 inletCfgCurrCritPhase2, inletCfgCurrCritPhase2b100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.6 inletCfgCurrCritPhase3, inletCfgCurrCritPhase3b100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.7 inletCfgCurrWarnPhase1, inletCfgCurrCritPhase1b200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.8 inletCfgCurrWarnPhase2, inletCfgCurrCritPhase2b200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.9 inletCfgCurrWarnPhase3, inletCfgCurrCritPhase3b200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.10 inletCfgVoltCritPhase1, inletCfgCurrWarnPhase1b100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.11 inletCfgVoltCritPhase2, inletCfgCurrWarnPhase2b100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.12 inletCfgVoltCritPhase3, inletCfgCurrWarnPhase3b100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.14 inletCfgVoltWarnPhase2, inletCfgCurrWarnPhase2b200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.15 inletCfgVoltWarnPhase3, inletCfgCurrWarnPhase3b200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.16 inletCfgVoltCritPhase100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.17 inletCfgVoltCritPhase200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.18 inletCfgVoltCritPhase300
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.19 inletCfgVoltWarnPhase100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.20 inletCfgVoltWarnPhase200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.21 inletCfgVoltWarnPhase300
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.22 inletCfgTotalCurrCritPhase100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.23 inletCfgTotalCurrCritPhase200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.24 inletCfgTotalCurrCritPhase300
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.25 inletCfgTotalCurrWarnPhase100
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.26 inletCfgTotalCurrWarnPhase200
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.27 inletCfgTotalCurrWarnPhase300
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.28 inletCfgRcmCurrThreshold00
1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.29 inletCfgLoadBalanceCrit00