OID reference

outletCtlPduCControl

1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2

Description

The control-type of PduC outlet.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1 (pduPwrMonitoringOutletCtlPduCEntry)
Node code
2
Node name
outletCtlPduCControl
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2
URN notation
urn:oid:1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 42610 1 4 4 1 6 2 3 4 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) sps(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) powertek(42610) product(1) pdu(4) pwt(4) pduObjects(1) pduPwrMonitoring(6) pduPwrMonitoringOutlet(2) pduPwrMonitoringOutletPduC(3) pduPwrMonitoringOutletCtlTablePduC(4) pduPwrMonitoringOutletCtlPduCEntry(1) outletCtlPduCControl(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/42610/1/4/4/1/6/2/3/4/1/2
  • /ISO/Identified-Organization/6/1/4/1/42610/1/4/4/1/6/2/3/4/1/2
  • /ISO/3/6/1/4/1/42610/1/4/4/1/6/2/3/4/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprise/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprise/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprise/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprises/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprises/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprises/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/enterprises/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/42610/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/42610/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/powertek/product/pdu/sps/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/powertek/product/pdu/pwt/pduObjects/pduPwrMonitoring/pduPwrMonitoringOutlet/pduPwrMonitoringOutletPduC/pduPwrMonitoringOutletCtlTablePduC/pduPwrMonitoringOutletCtlPduCEntry/outletCtlPduCControl
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1immediateOn2
1nothing1
2delayedOn2
2immediateOn1
3delayedOn1
3immediateOff2
4delayedOff2
4immediateOff1
5delayedOff1
5immediateCycle2
6delayedCycle2
6immediateCycle1
7delayedCycle1

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In SPSv1-MIB, the row index outletCtlPduCIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2.<outletCtlPduCIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

outletCtlPduCControl · mandatory

outletCtlPduCControl OBJECT-TYPE
        SYNTAX  INTEGER {
                nothing(1),
                immediateOn(2),
                delayedOn(3),
                immediateOff(4),
                delayedOff(5),
                immediateCycle(6),
                delayedCycle(7)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The control-type of PduC outlet."
        ::= { pduPwrMonitoringOutletCtlPduCEntry 2 }

outletCtlPduCControl · mandatory

outletCtlPduCControl OBJECT-TYPE
        SYNTAX  INTEGER {
                immediateOn(1),
                delayedOn(2),
                immediateOff(3),
                delayedOff(4),
                immediateCycle(5),
                delayedCycle(6)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The control-type of PduC outlet."
        ::= { pduPwrMonitoringOutletCtlPduCEntry 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The control-type of PduC outlet.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 records · 2 sources

Description 1

outletCtlPduCControl · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: outletCtlPduCControl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "outletCtlPduCControl",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "nothing",
    "(",
    "1",
    ")",
    ",",
    "immediateOn",
    "(",
    "2",
    ")",
    ",",
    "delayedOn",
    "(",
    "3",
    ")",
    ",",
    "immediateOff",
    "(",
    "4",
    ")",
    ",",
    "delayedOff",
    "(",
    "5",
    ")",
    ",",
    "immediateCycle",
    "(",
    "6",
    ")",
    ",",
    "delayedCycle",
    "(",
    "7",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The control-type of PduC outlet.\"",
    "::=",
    "{",
    "pduPwrMonitoringOutletCtlPduCEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "nothing",
            1
          ],
          [
            "immediateOn",
            2
          ],
          [
            "delayedOn",
            3
          ],
          [
            "immediateOff",
            4
          ],
          [
            "delayedOff",
            5
          ],
          [
            "immediateCycle",
            6
          ],
          [
            "delayedCycle",
            7
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The control-type of PduC outlet."
    ],
    null,
    null,
    null,
    null
  ]
}
outletCtlPduCControl · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: outletCtlPduCControl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "outletCtlPduCControl",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "immediateOn",
    "(",
    "1",
    ")",
    ",",
    "delayedOn",
    "(",
    "2",
    ")",
    ",",
    "immediateOff",
    "(",
    "3",
    ")",
    ",",
    "delayedOff",
    "(",
    "4",
    ")",
    ",",
    "immediateCycle",
    "(",
    "5",
    ")",
    ",",
    "delayedCycle",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The control-type of PduC outlet.\"",
    "::=",
    "{",
    "pduPwrMonitoringOutletCtlPduCEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "immediateOn",
            1
          ],
          [
            "delayedOn",
            2
          ],
          [
            "immediateOff",
            3
          ],
          [
            "delayedOff",
            4
          ],
          [
            "immediateCycle",
            5
          ],
          [
            "delayedCycle",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The control-type of PduC outlet."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.42610)

salvador trullols rico

Siblings (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.1 outletCtlPduCIndex00