portFlowCtrlStatus

1.3.6.1.4.1.43.35.8.3.1.1.9

Description

(2) BackPressure flow control machanism is used. (3) IEEE 802.3 flow control machanism is used. (4) Flow control mechanism is disabled. If this index is a trunk and the result is inconsistent among its member ports, this value is error(1).

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.43.35.8.3.1.1 (portEntry)
Node code
9
Node name
portFlowCtrlStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.43.35.8.3.1.1.9
URN notation
urn:oid:1.3.6.1.4.1.43.35.8.3.1.1.9
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 43 35 8 3 1 1 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3Com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3Com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) a3Com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) a3Com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) a3com(43) wlan-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) a3com(43) wlanAP-mib(35) rivet(8) enterpriseApPortMgnt(3) portTable(1) portEntry(1) portFlowCtrlStatus(9)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/43/35/8/3/1/1/9
  • /ISO/Identified-Organization/6/1/4/1/43/35/8/3/1/1/9
  • /ISO/3/6/1/4/1/43/35/8/3/1/1/9
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/a3Com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprise/a3Com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprise/a3com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprise/a3com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprises/a3Com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprises/a3Com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprises/a3com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/enterprises/a3com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/a3Com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/a3Com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/a3com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/a3com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/a3Com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/a3Com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/a3com/wlan-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/a3com/wlanAP-mib/rivet/enterpriseApPortMgnt/portTable/portEntry/portFlowCtrlStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1error
2backPressure
3dot3xFlowControl
4none

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In A3COM-PRIVATE-MIB, the row index portIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.43.35.8.3.1.1.9.<portIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.43.35.8.3.1.1.9

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

portFlowCtrlStatus OBJECT-TYPE
        SYNTAX      INTEGER
                    {
                        error(1),
                        backPressure(2),
                        dot3xFlowControl(3),
                        none(4)
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "(2) BackPressure flow control machanism is used.
                     (3) IEEE 802.3 flow control machanism is used.
                     (4) Flow control mechanism is disabled.
                     If this index is a trunk and the result
                     is inconsistent among its member ports, this value is
                     error(1)."
        ::= { portEntry 9 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

(2) BackPressure flow control machanism is used. (3) IEEE 802.3 flow control machanism is used. (4) Flow control mechanism is disabled. If this index is a trunk and the result is inconsistent among its member ports, this value is error(1).

Sources for this description

3Com MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 13Com MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

portFlowCtrlStatus · current3Com MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: portFlowCtrlStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "portFlowCtrlStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "error",
    "(",
    "1",
    ")",
    ",",
    "backPressure",
    "(",
    "2",
    ")",
    ",",
    "dot3xFlowControl",
    "(",
    "3",
    ")",
    ",",
    "none",
    "(",
    "4",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"(2) BackPressure flow control machanism is used. (3) IEEE 802.3 flow control machanism is used. (4) Flow control mechanism is disabled. If this index is a trunk and the result is inconsistent among its member ports, this value is error(1).\"",
    "::=",
    "{",
    "portEntry",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "error",
            1
          ],
          [
            "backPressure",
            2
          ],
          [
            "dot3xFlowControl",
            3
          ],
          [
            "none",
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "(2) BackPressure flow control machanism is used. (3) IEEE 802.3 flow control machanism is used. (4) Flow control mechanism is disabled. If this index is a trunk and the result is inconsistent among its member ports, this value is error(1)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.43)

Jeremy Siegel

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.43.35.8.3.1.1.1 portIndex00
1.3.6.1.4.1.43.35.8.3.1.1.2 portName00
1.3.6.1.4.1.43.35.8.3.1.1.3 portType00
1.3.6.1.4.1.43.35.8.3.1.1.4 portSpeedDpxCfg00
1.3.6.1.4.1.43.35.8.3.1.1.5 portFlowCtrlCfg00
1.3.6.1.4.1.43.35.8.3.1.1.6 portCapabilities00
1.3.6.1.4.1.43.35.8.3.1.1.7 portAutonegotiation00
1.3.6.1.4.1.43.35.8.3.1.1.8 portSpeedDpxStatus00