OID reference

h3cPOEThresholdACMaximum

1.3.6.1.4.1.43.45.1.10.2.14.8.1.2

Description

Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once,…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.43.45.1.10.2.14.8.1 (h3cPOEThresholdLimitObjs)
Node code
2
Node name
h3cPOEThresholdACMaximum
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.43.45.1.10.2.14.8.1.2
URN notation
urn:oid:1.3.6.1.4.1.43.45.1.10.2.14.8.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 43 45 1 10 2 14 8 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) a3Com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) a3com(43) jv-mib(45) huawei(1) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cPOEPowerObjects(8) h3cPOEThresholdLimitObjs(1) h3cPOEThresholdACMaximum(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/43/45/1/10/2/14/8/1/2
  • /ISO/Identified-Organization/6/1/4/1/43/45/1/10/2/14/8/1/2
  • /ISO/3/6/1/4/1/43/45/1/10/2/14/8/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/enterprise/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/enterprises/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/enterprises/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/vendor-objects/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/identified-organization/dod/internet/private/vendor-objects/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/enterprise/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/enterprise/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/enterprises/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/enterprises/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/ldap-enterprise/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/ldap-enterprise/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/vendor-objects/a3Com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • /iso/org/dod/internet/private/vendor-objects/a3com/jv-mib/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cPOEPowerObjects/h3cPOEThresholdLimitObjs/h3cPOEThresholdACMaximum
  • Additional combinations skipped.

SNMP properties

Value type
OCTET STRING
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed size (octets)
1–10

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.43.45.1.10.2.14.8.1.2.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

h3cPOEThresholdACMaximum · current

h3cPOEThresholdACMaximum OBJECT-TYPE
          SYNTAX OCTET STRING (SIZE (1..10))
          MAX-ACCESS read-write
          STATUS current
          DESCRIPTION
                 "Input threshold AC maximum.
                 It is a read-write node.
                 The value of this node is 'OCTET STRING',
                 it is used to describe a float value.
                 So this string should fit the following rule:
                 1. This string should be terminated by '\0';
                 2. Every characters should be number or radix point;
                 3. The radix point should occur only once, and it should not
                 be the first or the last character of the string.
                 It should be smaller than 264.0V and larger than 90.0V.
                 And it should be larger than the h3cPOEThresholdACMinimum."
          ::= { h3cPOEThresholdLimitObjs 2 }

h3cPOEThresholdACMaximum · current

h3cPOEThresholdACMaximum OBJECT-TYPE
          SYNTAX OCTET STRING (SIZE (1..10))
          MAX-ACCESS read-write
          STATUS current
          DESCRIPTION
                 "Input threshold AC maximum.
                 It is a read-write node.
                 The value of this node is 'OCTET STRING',
                 it is used to describe a float value.
                 So this string should fit the following rule:
                 1. This string should be terminated by '\0';
                 2. Every characters should be number or radix point;
                 3. The radix point should occur only once, and it should not
                 be the first or the last character of the string.
                 It should be smaller than 264.0V and larger than 90.0V.
                 And it should be larger than the h3cPOEThresholdACMinimum."
          ::= { h3cPOEThresholdLimitObjs 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the h3cPOEThresholdACMinimum.

Sources for this description

3Com MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 13Com MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies1 record · 2 sources

Description 1

h3cPOEThresholdACMaximum · current3Com MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies2 sources

Status in source: current.

Names: h3cPOEThresholdACMaximum

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "h3cPOEThresholdACMaximum",
    "OBJECT-TYPE",
    "SYNTAX",
    "OCTET",
    "STRING",
    "(",
    "SIZE",
    "(",
    "1",
    ".",
    ".",
    "10",
    ")",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the h3cPOEThresholdACMinimum.\"",
    "::=",
    "{",
    "h3cPOEThresholdLimitObjs",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OCTET STRING",
      [
        "octetStringSubType",
        [
          [
            1,
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the h3cPOEThresholdACMinimum."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.43)

Jeremy Siegel

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.43.45.1.10.2.14.8.1.1 h3cPOEThresholdACMimimum00
1.3.6.1.4.1.43.45.1.10.2.14.8.1.3 h3cPOEThresholdDCMinimum00
1.3.6.1.4.1.43.45.1.10.2.14.8.1.4 h3cPOEThresholdDCMaximum00