Broadcom proprietary MIB for runtime management of objects related to battery powered devices.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4413.2.2.2.1.10
Broadcom proprietary MIB for runtime management of objects related to battery powered devices.
Identification
{1 3 6 1 4 1 4413 2 2 2 1 10}
The displayed source records contain one distinct definition. Compare its source records.
batteryMgmt MODULE-IDENTITY
LAST-UPDATED "200912140000Z"
ORGANIZATION "Broadcom Corporation"
CONTACT-INFO
" BANANA-CABLEDATA
(cableData branch of the
Broadcom Assigned Numbers and Naming Authority)
Broadcom Corporation
Postal: 4385 River Green Parkway
Duluth, GA 30096
USA
Tel: +1 770 232-0018
E-mail: banana-cabledata@broadcom.com"
DESCRIPTION
"Broadcom proprietary MIB for runtime management of objects related
to battery powered devices."
REVISION "200912140000Z"
DESCRIPTION
"Added new alarm bcmAlarmLowPower"
REVISION "200903050000Z"
DESCRIPTION
"Corrected return values from battChargerLifeTestStatus and added notes
to battNextLifeTest"
REVISION "200810100000Z"
DESCRIPTION
"Added objects to facilitate automated testing of periodic life cycle test."
REVISION "200807100000Z"
DESCRIPTION
"Added objects for control of periodic life testing and hardware faults."
REVISION "200806180000Z"
DESCRIPTION
"Added group batteryThermalMgmt."
REVISION "200803210000Z"
DESCRIPTION
"Changed max-access of battChargerMaximumCharge to read-only."
REVISION "200709260000Z"
DESCRIPTION
"Added object battTemperature to the batteryTable."
REVISION "200702050000Z"
DESCRIPTION
"Module description was updated.
Compilability issues were cleaned up:
- Chronological order of revision history was corrected.
- Range restriction was added to object battIndex."
REVISION "200612080000Z"
DESCRIPTION
"Added alarm bcmAlarmTempBadDischargeInhibited.
Changed names of bcmAlarmBadTempChargeSuspended and
bcmAlarmBadTempPowerReduced to bcmAlarmTempBadChargeSuspended
and bcmAlarmTempBadPowerReduced for naming consistency with
upsAlarmTempBad from the UPS-MIB."
REVISION "200606200000Z"
DESCRIPTION
"Added objects related to per-pack EEPROM data to the batteryTable."
REVISION "200602080000Z"
DESCRIPTION
"Added object battErrors to the batteryTable."
REVISION "200602070100Z"
DESCRIPTION
"Added objects battEstimatedMinutesRemaining and
battEstimatedChargeRemaining to the batteryTable."
REVISION "200602070000Z"
DESCRIPTION
"Added alarms bcmAlarmBadTempChargeSuspended and
bcmAlarmBadTempPowerReduced."
REVISION "200512010000Z"
DESCRIPTION
"Added group batteryBcmAlarms and object
battChargerLowChargeThreshold."
REVISION "200508230000Z"
DESCRIPTION
"Added group batteryPowerMgmt."
REVISION "200504190000Z"
DESCRIPTION
"Added object battChargerReplaceBatteryThreshold."
REVISION "200502110000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { cableDataMgmtMIBObjects 10 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Broadcom proprietary MIB for runtime management of objects related to battery powered devices.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: batteryMgmt
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"batteryMgmt",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230303931323134303030305a22"
],
"ORGANIZATION",
"\"Broadcom Corporation\"",
"CONTACT-INFO",
"\" BANANA-CABLEDATA (cableData branch of the Broadcom Assigned Numbers and Naming Authority) Broadcom Corporation Postal: 4385 River Green Parkway Duluth, GA 30096 USA Tel: +1 770 232-0018 E-mail: banana-cabledata@broadcom.com\"",
"DESCRIPTION",
"\"Broadcom proprietary MIB for runtime management of objects related to battery powered devices.\"",
"REVISION",
[
"literal",
"223230303931323134303030305a22"
],
"DESCRIPTION",
"\"Added new alarm bcmAlarmLowPower\"",
"REVISION",
[
"literal",
"223230303930333035303030305a22"
],
"DESCRIPTION",
"\"Corrected return values from battChargerLifeTestStatus and added notes to battNextLifeTest\"",
"REVISION",
[
"literal",
"223230303831303130303030305a22"
],
"DESCRIPTION",
"\"Added objects to facilitate automated testing of periodic life cycle test.\"",
"REVISION",
[
"literal",
"223230303830373130303030305a22"
],
"DESCRIPTION",
"\"Added objects for control of periodic life testing and hardware faults.\"",
"REVISION",
[
"literal",
"223230303830363138303030305a22"
],
"DESCRIPTION",
"\"Added group batteryThermalMgmt.\"",
"REVISION",
[
"literal",
"223230303830333231303030305a22"
],
"DESCRIPTION",
"\"Changed max-access of battChargerMaximumCharge to read-only.\"",
"REVISION",
[
"literal",
"223230303730393236303030305a22"
],
"DESCRIPTION",
"\"Added object battTemperature to the batteryTable.\"",
"REVISION",
[
"literal",
"223230303730323035303030305a22"
],
"DESCRIPTION",
"\"Module description was updated. Compilability issues were cleaned up: - Chronological order of revision history was corrected. - Range restriction was added to object battIndex.\"",
"REVISION",
[
"literal",
"223230303631323038303030305a22"
],
"DESCRIPTION",
"\"Added alarm bcmAlarmTempBadDischargeInhibited. Changed names of bcmAlarmBadTempChargeSuspended and bcmAlarmBadTempPowerReduced to bcmAlarmTempBadChargeSuspended and bcmAlarmTempBadPowerReduced for naming consistency with upsAlarmTempBad from the UPS-MIB.\"",
"REVISION",
[
"literal",
"223230303630363230303030305a22"
],
"DESCRIPTION",
"\"Added objects related to per-pack EEPROM data to the batteryTable.\"",
"REVISION",
[
"literal",
"223230303630323038303030305a22"
],
"DESCRIPTION",
"\"Added object battErrors to the batteryTable.\"",
"REVISION",
[
"literal",
"223230303630323037303130305a22"
],
"DESCRIPTION",
"\"Added objects battEstimatedMinutesRemaining and battEstimatedChargeRemaining to the batteryTable.\"",
"REVISION",
[
"literal",
"223230303630323037303030305a22"
],
"DESCRIPTION",
"\"Added alarms bcmAlarmBadTempChargeSuspended and bcmAlarmBadTempPowerReduced.\"",
"REVISION",
[
"literal",
"223230303531323031303030305a22"
],
"DESCRIPTION",
"\"Added group batteryBcmAlarms and object battChargerLowChargeThreshold.\"",
"REVISION",
[
"literal",
"223230303530383233303030305a22"
],
"DESCRIPTION",
"\"Added group batteryPowerMgmt.\"",
"REVISION",
[
"literal",
"223230303530343139303030305a22"
],
"DESCRIPTION",
"\"Added object battChargerReplaceBatteryThreshold.\"",
"REVISION",
[
"literal",
"223230303530323131303030305a22"
],
"DESCRIPTION",
"\"Initial version of this MIB module.\"",
"::=",
"{",
"cableDataMgmtMIBObjects",
"10",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"200912140000Z"
],
[
"ORGANIZATION",
"Broadcom Corporation"
],
[
"CONTACT-INFO",
"BANANA-CABLEDATA (cableData branch of the Broadcom Assigned Numbers and Naming Authority) Broadcom Corporation Postal: 4385 River Green Parkway Duluth, GA 30096 USA Tel: +1 770 232-0018 E-mail: banana-cabledata@broadcom.com"
],
[
"DESCRIPTION",
"Broadcom proprietary MIB for runtime management of objects related to battery powered devices."
],
[
"Revisions",
[
[
"200912140000Z",
[
"DESCRIPTION",
"Added new alarm bcmAlarmLowPower"
]
],
[
"200903050000Z",
[
"DESCRIPTION",
"Corrected return values from battChargerLifeTestStatus and added notes to battNextLifeTest"
]
],
[
"200810100000Z",
[
"DESCRIPTION",
"Added objects to facilitate automated testing of periodic life cycle test."
]
],
[
"200807100000Z",
[
"DESCRIPTION",
"Added objects for control of periodic life testing and hardware faults."
]
],
[
"200806180000Z",
[
"DESCRIPTION",
"Added group batteryThermalMgmt."
]
],
[
"200803210000Z",
[
"DESCRIPTION",
"Changed max-access of battChargerMaximumCharge to read-only."
]
],
[
"200709260000Z",
[
"DESCRIPTION",
"Added object battTemperature to the batteryTable."
]
],
[
"200702050000Z",
[
"DESCRIPTION",
"Module description was updated. Compilability issues were cleaned up: - Chronological order of revision history was corrected. - Range restriction was added to object battIndex."
]
],
[
"200612080000Z",
[
"DESCRIPTION",
"Added alarm bcmAlarmTempBadDischargeInhibited. Changed names of bcmAlarmBadTempChargeSuspended and bcmAlarmBadTempPowerReduced to bcmAlarmTempBadChargeSuspended and bcmAlarmTempBadPowerReduced for naming consistency with upsAlarmTempBad from the UPS-MIB."
]
],
[
"200606200000Z",
[
"DESCRIPTION",
"Added objects related to per-pack EEPROM data to the batteryTable."
]
],
[
"200602080000Z",
[
"DESCRIPTION",
"Added object battErrors to the batteryTable."
]
],
[
"200602070100Z",
[
"DESCRIPTION",
"Added objects battEstimatedMinutesRemaining and battEstimatedChargeRemaining to the batteryTable."
]
],
[
"200602070000Z",
[
"DESCRIPTION",
"Added alarms bcmAlarmBadTempChargeSuspended and bcmAlarmBadTempPowerReduced."
]
],
[
"200512010000Z",
[
"DESCRIPTION",
"Added group batteryBcmAlarms and object battChargerLowChargeThreshold."
]
],
[
"200508230000Z",
[
"DESCRIPTION",
"Added group batteryPowerMgmt."
]
],
[
"200504190000Z",
[
"DESCRIPTION",
"Added object battChargerReplaceBatteryThreshold."
]
],
[
"200502110000Z",
[
"DESCRIPTION",
"Initial version of this MIB module."
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: BRCM-BATTERY-MGMT-MIB
See published definition above
{'UPS-MIB': ['PositiveInteger'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'BRCM-CABLEDATA-MGMT-MIB': ['cableDataMgmtMIBObjects']}Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download BRCM-BATTERY-MGMT-MIBRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4413.2.2.2.1.10.1 | batteryMgmtBase | 1 | 28 | |
| 1.3.6.1.4.1.4413.2.2.2.1.10.2 | batteryCharger | 14 | 14 | |
| 1.3.6.1.4.1.4413.2.2.2.1.10.3 | batteryPowerMgmt | 1 | 7 | |
| 1.3.6.1.4.1.4413.2.2.2.1.10.4 | batteryBcmAlarms | 7 | 7 | |
| 1.3.6.1.4.1.4413.2.2.2.1.10.5 | batteryThermalMgmt | 1 | 6 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4413.2.2.2.1.1 | cableDataMgmtBase | 5 | 72 | |
| 1.3.6.1.4.1.4413.2.2.2.1.2 | cablemodemMgmt | 6 | 74 | |
| 1.3.6.1.4.1.4413.2.2.2.1.3 | cablehomeMgmt | 1 | 2 | |
| 1.3.6.1.4.1.4413.2.2.2.1.4 | v2Mgmt | 1 | 1 | |
| 1.3.6.1.4.1.4413.2.2.2.1.5 | ieee802dot11Mgmt | 5 | 94 | |
| 1.3.6.1.4.1.4413.2.2.2.1.7 | residentialGatewayMgmt | 2 | 52 | |
| 1.3.6.1.4.1.4413.2.2.2.1.8 | parentalControlMgmt | 1 | 10 | |
| 1.3.6.1.4.1.4413.2.2.2.1.9 | bfcMgmt | 1 | 36 | |
| 1.3.6.1.4.1.4413.2.2.2.1.11 | thermalMgmt | 1 | 8 | |
| 1.3.6.1.4.1.4413.2.2.2.1.12 | ftpMgmt | 13 | 13 | |
| 1.3.6.1.4.1.4413.2.2.2.1.13 | brcmIptvMgmt | 1 | 19 |