1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4

Description

A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.4413.2.99.1.1.2.2.4 (cmFactoryUpstreamCalibration)
Node code
4
Node name
cmUsCalTxPower
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4
URN notation
urn:oid:1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 4413 2 99 1 1 2 2 4 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataFactory(2) cablemodemFactory(2) cmFactoryUpstreamCalibration(4) cmUsCalTxPower(4)}
OID-IRI notation
  • /1/3/6/1/4/1/4413/2/99/1/1/2/2/4/4
  • /ISO/Identified-Organization/6/1/4/1/4413/2/99/1/1/2/2/4/4
  • /ISO/3/6/1/4/1/4413/2/99/1/1/2/2/4/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/identified-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/identified-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/org/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/org/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/org/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/org/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-identified-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-identified-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower
  • /iso/iso-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataFactory/cablemodemFactory/cmFactoryUpstreamCalibration/cmUsCalTxPower

SNMP properties

Value type
Integer32
Units
hundredth dBmV
Maximum access defined by MIB
read-write
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

cmUsCalTxPower OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "hundredth dBmV" 
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "A set of this object will cause the CM to begin transmitting upstream
        at the specified power level to the best of its ability based on 
        current upstream calibration parameters.  cmUsCalModulation and
        cmUsCalFrequency will be used to determine the modulation scheme and
        transmit power that will be used."
    REFERENCE 
       "docsIfCmStatusTxPower from DOCS-IF-MIB" 
    ::= { cmFactoryUpstreamCalibration 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

cmUsCalTxPower · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: cmUsCalTxPower

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cmUsCalTxPower",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "UNITS",
    [
      "literal",
      "2268756e6472656474682064426d5622"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used.\"",
    "REFERENCE",
    "\"docsIfCmStatusTxPower from DOCS-IF-MIB\"",
    "::=",
    "{",
    "cmFactoryUpstreamCalibration",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    [
      "UNITS",
      "hundredth dBmV"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used."
    ],
    [
      "REFERENCE",
      "docsIfCmStatusTxPower from DOCS-IF-MIB"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4413)

Fan Frankie

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.1 cmUsCalFrequency00
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.2 cmUsCalChannelWidth00
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.3 cmUsCalModulation00
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.5 cmUsCalZeroOffsets00
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.6 cmUsCalNumOffsets00
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.7 cmUsCalOffsetTable14
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.8 cmUsCalChannelNumber00