Description

This object can be used to simulate transitions to and from different power sources for the purpose of evaluating system response to such transitions. Setting the object to utility(1) will dispatch an event indicating transition to utility power. Setting the object to battery(2) will dispatch an event indicating trans…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.4413.2.99.1.1.3.10.1 (batteryEngrBase)
Node code
1
Node name
battSimulatePowerSource
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.4413.2.99.1.1.3.10.1.1
URN notation
urn:oid:1.3.6.1.4.1.4413.2.99.1.1.3.10.1.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 4413 2 99 1 1 3 10 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) batteryEngineering(10) batteryEngrBase(1) battSimulatePowerSource(1)}
OID-IRI notation
  • /1/3/6/1/4/1/4413/2/99/1/1/3/10/1/1
  • /ISO/Identified-Organization/6/1/4/1/4413/2/99/1/1/3/10/1/1
  • /ISO/3/6/1/4/1/4413/2/99/1/1/3/10/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/identified-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/identified-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/org/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/org/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/org/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/org/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-identified-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-identified-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource
  • /iso/iso-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/batteryEngineering/batteryEngrBase/battSimulatePowerSource

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

ValueName
0none
1utility
2battery

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.4413.2.99.1.1.3.10.1.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

battSimulatePowerSource OBJECT-TYPE
    SYNTAX      INTEGER {
                none(0),
                utility(1),
				battery(2)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object can be used to simulate transitions to and from different
         power sources for the purpose of evaluating system response to such
         transitions.  Setting the object to utility(1) will dispatch an event
         indicating transition to utility power.  Setting the object to 
         battery(2) will dispatch an event indicating transition to battery 
         power.  Setting the object to none(0) will dispatch an event indicating
         a transition to the actual current power source, thus returning the
         system state to its actual current condition.
         
         Note that setting this object does not actually result in a power 
         source change, only in the publishing of an event that the power source
         has changed.  As a result, the object may be set to battery(2) even if
         no battery is installed, or utility(1) if the device is not currently
         attached to utility power.
         
         Further note that setting this object does not affect battery charging,
         state reported by objects in the BRCM-BATTERY-MGMT-MIB or UPS-MIB, etc."
    ::= { batteryEngrBase 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This object can be used to simulate transitions to and from different power sources for the purpose of evaluating system response to such transitions. Setting the object to utility(1) will dispatch an event indicating transition to utility power. Setting the object to battery(2) will dispatch an event indicating transition to battery power. Setting the object to none(0) will dispatch an event indicating a transition to the actual current power source, thus returning the system state to its actual current condition. Note that setting this object does not actually result in a power source change, only in the publishing of an event that the power source has changed. As a result, the object may be set to battery(2) even if no battery is installed, or utility(1) if the device is not currently attached to utility power. Further note that setting this object does not affect battery charging, state reported by objects in the BRCM-BATTERY-MGMT-MIB or UPS-MIB, etc.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

battSimulatePowerSource · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: battSimulatePowerSource

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "battSimulatePowerSource",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "none",
    "(",
    "0",
    ")",
    ",",
    "utility",
    "(",
    "1",
    ")",
    ",",
    "battery",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object can be used to simulate transitions to and from different power sources for the purpose of evaluating system response to such transitions. Setting the object to utility(1) will dispatch an event indicating transition to utility power. Setting the object to battery(2) will dispatch an event indicating transition to battery power. Setting the object to none(0) will dispatch an event indicating a transition to the actual current power source, thus returning the system state to its actual current condition. Note that setting this object does not actually result in a power source change, only in the publishing of an event that the power source has changed. As a result, the object may be set to battery(2) even if no battery is installed, or utility(1) if the device is not currently attached to utility power. Further note that setting this object does not affect battery charging, state reported by objects in the BRCM-BATTERY-MGMT-MIB or UPS-MIB, etc.\"",
    "::=",
    "{",
    "batteryEngrBase",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "none",
            0
          ],
          [
            "utility",
            1
          ],
          [
            "battery",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object can be used to simulate transitions to and from different power sources for the purpose of evaluating system response to such transitions. Setting the object to utility(1) will dispatch an event indicating transition to utility power. Setting the object to battery(2) will dispatch an event indicating transition to battery power. Setting the object to none(0) will dispatch an event indicating a transition to the actual current power source, thus returning the system state to its actual current condition. Note that setting this object does not actually result in a power source change, only in the publishing of an event that the power source has changed. As a result, the object may be set to battery(2) even if no battery is installed, or utility(1) if the device is not currently attached to utility power. Further note that setting this object does not affect battery charging, state reported by objects in the BRCM-BATTERY-MGMT-MIB or UPS-MIB, etc."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4413)

Fan Frankie