Broadcom proprietary MIB for management and configuration of cablemodem objects used in engineering and development.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4413.2.99.1.1.3.2
Broadcom proprietary MIB for management and configuration of cablemodem objects used in engineering and development.
Identification
{1 3 6 1 4 1 4413 2 99 1 1 3 2}
The displayed source records contain one distinct definition. Compare its source records.
cablemodemEngineering MODULE-IDENTITY
LAST-UPDATED "201104140000Z"
ORGANIZATION "Broadcom Corporation"
CONTACT-INFO
" BANANA-CABLEDATA
(cableData branch of the
Broadcom Assigned Numbers and Naming Authority)
Broadcom Corporation
Postal: 4385 River Green Parkway
Duluth, GA 30096
USA
Tel: +1 770 232-0018
E-mail: banana-cabledata@broadcom.com"
DESCRIPTION
"Broadcom proprietary MIB for management and configuration
of cablemodem objects used in engineering and development."
REVISION "201104140000Z"
DESCRIPTION
"Added object cmDsCalPhySymbolRate."
REVISION "201010200000Z"
DESCRIPTION
"Updated value ranges on cmDsCalTunerIndex, cmDsCalPhyTuner and
cmDsCalPhyTunerChannel."
REVISION "200910060000Z"
DESCRIPTION
"Added cmEngrBpi objects.
Removed DEFVAL from cmDsCalTunerType object to fix compiler warning."
REVISION "200904030000Z"
DESCRIPTION
"Added object cmUsCalDiplexer."
REVISION "200811030000Z"
DESCRIPTION
"Added objects cmDsCalPhyFrequency and cmDsCalPhyFrequencyError."
REVISION "200809230000Z"
DESCRIPTION
"Added cmDsCalTunerTable and cmDsCalPhyTable in support of systems
which support multiple DS phys per tuner."
REVISION "200702050000Z"
DESCRIPTION
"Module description was updated.
Compilability issues were cleaned up:
- Chronological order of revision history was corrected.
- Revision dates were updated to post-Y2K format.
- Range restrictions were added to objects cmDsCalTunerCoefIndex,
cmDsCalIFCoefIndex, cmDsCalFineCoefIndex, cmDsCalEqCoefIndex, and
cmUsCalControlIndex."
REVISION "200306230000Z"
DESCRIPTION
"Added objects to allow dynamic population and de-population of
the downstream and upstream calibration tables in order to provide
more efficient RAM management when performing downstream and
upstream CM characterization."
REVISION "200304240000Z"
DESCRIPTION
"Added cmDsCalFrequencyError object."
REVISION "200301030000Z"
DESCRIPTION
"Added cmHwSTABW2 object."
REVISION "200212230000Z"
DESCRIPTION
"Added AGC control objects. Ho, Ho, Ho."
REVISION "200212110000Z"
DESCRIPTION
"Added more DS cal objects to control and report the results of the
CM DS characterization routine."
REVISION "200211110000Z"
DESCRIPTION
"Added objects for 33xx hardware control in cmEngrBase and
populated cmEngrUpstreamCalibration."
REVISION "200210220000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { cableDataEngineering 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Broadcom proprietary MIB for management and configuration of cablemodem objects used in engineering and development.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: cablemodemEngineering
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"cablemodemEngineering",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313130343134303030305a22"
],
"ORGANIZATION",
"\"Broadcom Corporation\"",
"CONTACT-INFO",
"\" BANANA-CABLEDATA (cableData branch of the Broadcom Assigned Numbers and Naming Authority) Broadcom Corporation Postal: 4385 River Green Parkway Duluth, GA 30096 USA Tel: +1 770 232-0018 E-mail: banana-cabledata@broadcom.com\"",
"DESCRIPTION",
"\"Broadcom proprietary MIB for management and configuration of cablemodem objects used in engineering and development.\"",
"REVISION",
[
"literal",
"223230313130343134303030305a22"
],
"DESCRIPTION",
"\"Added object cmDsCalPhySymbolRate.\"",
"REVISION",
[
"literal",
"223230313031303230303030305a22"
],
"DESCRIPTION",
"\"Updated value ranges on cmDsCalTunerIndex, cmDsCalPhyTuner and cmDsCalPhyTunerChannel.\"",
"REVISION",
[
"literal",
"223230303931303036303030305a22"
],
"DESCRIPTION",
"\"Added cmEngrBpi objects. Removed DEFVAL from cmDsCalTunerType object to fix compiler warning.\"",
"REVISION",
[
"literal",
"223230303930343033303030305a22"
],
"DESCRIPTION",
"\"Added object cmUsCalDiplexer.\"",
"REVISION",
[
"literal",
"223230303831313033303030305a22"
],
"DESCRIPTION",
"\"Added objects cmDsCalPhyFrequency and cmDsCalPhyFrequencyError.\"",
"REVISION",
[
"literal",
"223230303830393233303030305a22"
],
"DESCRIPTION",
"\"Added cmDsCalTunerTable and cmDsCalPhyTable in support of systems which support multiple DS phys per tuner.\"",
"REVISION",
[
"literal",
"223230303730323035303030305a22"
],
"DESCRIPTION",
"\"Module description was updated. Compilability issues were cleaned up: - Chronological order of revision history was corrected. - Revision dates were updated to post-Y2K format. - Range restrictions were added to objects cmDsCalTunerCoefIndex, cmDsCalIFCoefIndex, cmDsCalFineCoefIndex, cmDsCalEqCoefIndex, and cmUsCalControlIndex.\"",
"REVISION",
[
"literal",
"223230303330363233303030305a22"
],
"DESCRIPTION",
"\"Added objects to allow dynamic population and de-population of the downstream and upstream calibration tables in order to provide more efficient RAM management when performing downstream and upstream CM characterization.\"",
"REVISION",
[
"literal",
"223230303330343234303030305a22"
],
"DESCRIPTION",
"\"Added cmDsCalFrequencyError object.\"",
"REVISION",
[
"literal",
"223230303330313033303030305a22"
],
"DESCRIPTION",
"\"Added cmHwSTABW2 object.\"",
"REVISION",
[
"literal",
"223230303231323233303030305a22"
],
"DESCRIPTION",
"\"Added AGC control objects. Ho, Ho, Ho.\"",
"REVISION",
[
"literal",
"223230303231323131303030305a22"
],
"DESCRIPTION",
"\"Added more DS cal objects to control and report the results of the CM DS characterization routine.\"",
"REVISION",
[
"literal",
"223230303231313131303030305a22"
],
"DESCRIPTION",
"\"Added objects for 33xx hardware control in cmEngrBase and populated cmEngrUpstreamCalibration.\"",
"REVISION",
[
"literal",
"223230303231303232303030305a22"
],
"DESCRIPTION",
"\"Initial version of this MIB module.\"",
"::=",
"{",
"cableDataEngineering",
"2",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201104140000Z"
],
[
"ORGANIZATION",
"Broadcom Corporation"
],
[
"CONTACT-INFO",
"BANANA-CABLEDATA (cableData branch of the Broadcom Assigned Numbers and Naming Authority) Broadcom Corporation Postal: 4385 River Green Parkway Duluth, GA 30096 USA Tel: +1 770 232-0018 E-mail: banana-cabledata@broadcom.com"
],
[
"DESCRIPTION",
"Broadcom proprietary MIB for management and configuration of cablemodem objects used in engineering and development."
],
[
"Revisions",
[
[
"201104140000Z",
[
"DESCRIPTION",
"Added object cmDsCalPhySymbolRate."
]
],
[
"201010200000Z",
[
"DESCRIPTION",
"Updated value ranges on cmDsCalTunerIndex, cmDsCalPhyTuner and cmDsCalPhyTunerChannel."
]
],
[
"200910060000Z",
[
"DESCRIPTION",
"Added cmEngrBpi objects. Removed DEFVAL from cmDsCalTunerType object to fix compiler warning."
]
],
[
"200904030000Z",
[
"DESCRIPTION",
"Added object cmUsCalDiplexer."
]
],
[
"200811030000Z",
[
"DESCRIPTION",
"Added objects cmDsCalPhyFrequency and cmDsCalPhyFrequencyError."
]
],
[
"200809230000Z",
[
"DESCRIPTION",
"Added cmDsCalTunerTable and cmDsCalPhyTable in support of systems which support multiple DS phys per tuner."
]
],
[
"200702050000Z",
[
"DESCRIPTION",
"Module description was updated. Compilability issues were cleaned up: - Chronological order of revision history was corrected. - Revision dates were updated to post-Y2K format. - Range restrictions were added to objects cmDsCalTunerCoefIndex, cmDsCalIFCoefIndex, cmDsCalFineCoefIndex, cmDsCalEqCoefIndex, and cmUsCalControlIndex."
]
],
[
"200306230000Z",
[
"DESCRIPTION",
"Added objects to allow dynamic population and de-population of the downstream and upstream calibration tables in order to provide more efficient RAM management when performing downstream and upstream CM characterization."
]
],
[
"200304240000Z",
[
"DESCRIPTION",
"Added cmDsCalFrequencyError object."
]
],
[
"200301030000Z",
[
"DESCRIPTION",
"Added cmHwSTABW2 object."
]
],
[
"200212230000Z",
[
"DESCRIPTION",
"Added AGC control objects. Ho, Ho, Ho."
]
],
[
"200212110000Z",
[
"DESCRIPTION",
"Added more DS cal objects to control and report the results of the CM DS characterization routine."
]
],
[
"200211110000Z",
[
"DESCRIPTION",
"Added objects for 33xx hardware control in cmEngrBase and populated cmEngrUpstreamCalibration."
]
],
[
"200210220000Z",
[
"DESCRIPTION",
"Initial version of this MIB module."
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: BRCM-CM-ENGINEERING-MIB
See published definition above
{'SNMPv2-TC': ['TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'DOCS-IF-MIB': ['TenthdBmV', 'TenthdB'], 'BRCM-CM-FACTORY-MIB': ['cmDsCalOffsetIndex'], 'BRCM-CABLEDATA-ENGINEERING-MIB': ['cableDataEngineering']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4413.2.99.1.1.3.2.1 | cmEngrBase | 3 | 3 | |
| 1.3.6.1.4.1.4413.2.99.1.1.3.2.2 | cmEngrDownstreamCalibration | 33 | 72 | |
| 1.3.6.1.4.1.4413.2.99.1.1.3.2.3 | cmEngrUpstreamCalibration | 15 | 20 | |
| 1.3.6.1.4.1.4413.2.99.1.1.3.2.4 | cmEngrHardware | 5 | 5 | |
| 1.3.6.1.4.1.4413.2.99.1.1.3.2.5 | cmEngrBpi | 4 | 4 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4413.2.99.1.1.3.1 | cableDataEngineeringBase | 5 | 23 | |
| 1.3.6.1.4.1.4413.2.99.1.1.3.10 | batteryEngineering | 1 | 2 |