TMU may be active or passive. This indicates the currents state.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.4458.1000.1.1.72.2.1.2
TMU may be active or passive. This indicates the currents state.
Identification
{1 3 6 1 4 1 4458 1000 1 1 72 2 1 2}
| Value | Name |
|---|---|
| 1 | active |
| 2 | passive |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4458.1000.1.1.72.2.1.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
winlink1000OduAdminFiMMUAirRole OBJECT-TYPE
SYNTAX INTEGER {
active (1),
passive (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TMU may be active or passive. This indicates the currents state."
::= { winlink1000OduAdmFiMMUAir 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
TMU may be active or passive. This indicates the currents state.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: winlink1000OduAdminFiMMUAirRole
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"winlink1000OduAdminFiMMUAirRole",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"active",
"(",
"1",
")",
",",
"passive",
"(",
"2",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"TMU may be active or passive. This indicates the currents state.\"",
"::=",
"{",
"winlink1000OduAdmFiMMUAir",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"active",
1
],
[
"passive",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"TMU may be active or passive. This indicates the currents state."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RADWIN-MIB-WINLINK1000
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: RADWIN-MIB-WINLINK1000
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4458.1000.1.1.72.2.1.1 | winlink1000OduAdminFiMMUAirServBS | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.1.72.2.1.3 | winlink1000OduAdminFiMMUAirHOMode | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.1.72.2.1.4 | winlink1000OduAdminFiMMUAirIBHOType | 0 | 0 |