ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1).
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.4458.1000.1.4.4.101
ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1).
Identification
{1 3 6 1 4 1 4458 1000 1 4 4 101}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4458.1000.1.4.4.101.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
winlink1000OduBridgeTpMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU bridge mode.
A change is effective after reset. Valid values: hubMode (0), bridgeMode (1)."
::= { winlink1000OduBridgeTp 101 }winlink1000OduBridgeTpMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU bridge mode.
A change is effective after reset. Valid values: hubMode (0), bridgeMode (1)."
::= { winlink1000OduBridgeTp 101 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1).
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: winlink1000OduBridgeTpMode
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"winlink1000OduBridgeTpMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1).\"",
"::=",
"{",
"winlink1000OduBridgeTp",
"101",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RADWIN-MIB-WINLINK1000
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: RADWIN-MIB-WINLINK1000
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4458.1000.1.4.4.3 | winlink1000OduBridgeTpPortTable | 1 | 6 | |
| 1.3.6.1.4.1.4458.1000.1.4.4.102 | winlink1000OduBridgeConfigMode | 0 | 0 |