Number of correct blocks transmitted to the line.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.4458.1000.2.6.7.1.101
Number of correct blocks transmitted to the line.
Identification
{1 3 6 1 4 1 4458 1000 2 6 7 1 101}
A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.
Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.
Published counter width: 32 bits. SMIv2: Counter32 · Counter64
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In RADWIN-MIB-WINLINK1000, the row index winlink1000IduTdmCurrentIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.4458.1000.2.6.7.1.101.<winlink1000IduTdmCurrentIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4458.1000.2.6.7.1.101
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
winlink1000IduTdmCurrentBlocks OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of correct blocks transmitted to the line."
::= { winlink1000IduTdmCurrentEntry 101 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Number of correct blocks transmitted to the line.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: winlink1000IduTdmCurrentBlocks
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"winlink1000IduTdmCurrentBlocks",
"OBJECT-TYPE",
"SYNTAX",
"Counter",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Number of correct blocks transmitted to the line.\"",
"::=",
"{",
"winlink1000IduTdmCurrentEntry",
"101",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Number of correct blocks transmitted to the line."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RADWIN-MIB-WINLINK1000
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: RADWIN-MIB-WINLINK1000
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4458.1000.2.6.7.1.1 | winlink1000IduTdmCurrentIndex | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.2.6.7.1.102 | winlink1000IduTdmCurrentDrops | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.2.6.7.1.103 | winlink1000IduTdmCurrentTxClock | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.2.6.7.1.104 | winlink1000IduTdmCurrentBlocksHigh | 0 | 0 |