Reference record for OID 1.3.6.1.4.1.4491.2.1.27.1.2.5

Parent
1.3.6.1.4.1.4491.2.1.27.1.2 (docsPnmCmObjects)
Node code
5
Node name
docsPnmCmDsOfdmRxMerTable
Numeric OID
1.3.6.1.4.1.4491.2.1.27.1.2.5
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.27.1.2.5
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 27 1 2 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsPnmMIB(27) docsPnmMibObjects(1) docsPnmCmObjects(2) docsPnmCmDsOfdmRxMerTable(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/27/1/2/5
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/27/1/2/5
  • /ISO/3/6/1/4/1/4491/2/1/27/1/2/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/vendor-objects/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/identified-organization/dod/internet/private/vendor-objects/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/ldap-enterprise/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/ldap-enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/vendor-objects/cableLabs/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • /iso/org/dod/internet/private/vendor-objects/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsPnmMIB/docsPnmMibObjects/docsPnmCmObjects/docsPnmCmDsOfdmRxMerTable
  • Additional combinations skipped.

Descriptions

docsPnmCmDsOfdmRxMerTable — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

This item provides measurements of the receive modulation error ratio (RxMER) for each subcarrier. Each subcarrier RxMER value consists of one byte which represents the RxMER value with range 0 to 63.5 dB in 0.25 dB steps. If some subcarriers (such as exclusion bands) cannot be measured by the CM, the CM indicates that condition by reporting a value of 0xFF for the RxMER for those subcarriers. Any measured RxMER value below 0 dB is clipped to 0 dB (0x00), and any measured value above 63.5 dB is clipped to 63.5 dB (0xFE). Mathematical notation for the calculation of RxMER is provided in [PHYv3.1]: 'Downstream Receive Modulation Error Ratio (RxMER) Per Subcarrier'. This table will have a row for each ifIndex for the modem.

Source records

docsPnmCmDsOfdmRxMerTable

Status in source: current.

Names: docsPnmCmDsOfdmRxMerTable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsPnmCmDsOfdmRxMerTable",
    "OBJECT-TYPE",
    "SYNTAX",
    "SEQUENCE",
    "OF",
    "DocsPnmCmDsOfdmRxMerEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This item provides measurements of the receive modulation error ratio (RxMER) for each subcarrier. Each subcarrier RxMER value consists of one byte which represents the RxMER value with range 0 to 63.5 dB in 0.25 dB steps. If some subcarriers (such as exclusion bands) cannot be measured by the CM, the CM indicates that condition by reporting a value of 0xFF for the RxMER for those subcarriers. Any measured RxMER value below 0 dB is clipped to 0 dB (0x00), and any measured value above 63.5 dB is clipped to 63.5 dB (0xFE). Mathematical notation for the calculation of RxMER is provided in [PHYv3.1]: 'Downstream Receive Modulation Error Ratio (RxMER) Per Subcarrier'. This table will have a row for each ifIndex for the modem. \"",
    "REFERENCE",
    "\"DOCSIS 3.1 Cable Modem Operations Support System Interface Specification CM-SP-CM-OSSIv3.1, PNM section.\"",
    "::=",
    "{",
    "docsPnmCmObjects",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "conceptualTable",
      [
        "row",
        "DocsPnmCmDsOfdmRxMerEntry"
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This item provides measurements of the receive modulation error ratio (RxMER) for each subcarrier. Each subcarrier RxMER value consists of one byte which represents the RxMER value with range 0 to 63.5 dB in 0.25 dB steps. If some subcarriers (such as exclusion bands) cannot be measured by the CM, the CM indicates that condition by reporting a value of 0xFF for the RxMER for those subcarriers. Any measured RxMER value below 0 dB is clipped to 0 dB (0x00), and any measured value above 63.5 dB is clipped to 63.5 dB (0xFE). Mathematical notation for the calculation of RxMER is provided in [PHYv3.1]: 'Downstream Receive Modulation Error Ratio (RxMER) Per Subcarrier'. This table will have a row for each ifIndex for the modem."
    ],
    [
      "REFERENCE",
      "DOCSIS 3.1 Cable Modem Operations Support System Interface Specification CM-SP-CM-OSSIv3.1, PNM section."
    ],
    null,
    null,
    null
  ]
}
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive.

    Module: DOCS-PNM-MIB

    Published definition
    docsPnmCmDsOfdmRxMerTable OBJECT-TYPE
         SYNTAX      SEQUENCE OF DocsPnmCmDsOfdmRxMerEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
            "This item provides measurements of the receive modulation error ratio
            (RxMER) for each subcarrier. Each subcarrier RxMER value consists of one
            byte which represents the RxMER value with range 0 to 63.5 dB in 0.25 dB
            steps. If some subcarriers (such as exclusion bands) cannot be measured
            by the CM, the CM indicates that condition by reporting a value of 0xFF
            for the RxMER for those subcarriers. Any measured RxMER value below 0 dB
            is clipped to 0 dB (0x00), and any measured value above 63.5 dB is clipped
            to 63.5 dB (0xFE).
    
            Mathematical notation for the calculation of RxMER is provided in [PHYv3.1]:
            'Downstream Receive Modulation Error Ratio (RxMER) Per Subcarrier'.
    
            This table will have a row for each ifIndex for the modem. "
         REFERENCE
            "DOCSIS 3.1 Cable Modem Operations Support System Interface
             Specification CM-SP-CM-OSSIv3.1, PNM section."
         ::= { docsPnmCmObjects 5}
    Module imports
    {'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'DOCS-IF-MIB': ['TenthdB'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['docsIf3CmSpectrumAnalysisCtrlCmd'], 'DOCS-IF31-MIB': ['DsOfdmModulationType'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-PNM-MIB

    Related source files and packages:


    Source location: DOCS-PNM-MIB::docsPnmCmDsOfdmRxMerTable.
    Source version and references

    Downloaded: 2026-10-24T02:14:27.031149+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.27.1.2.5.1 docsPnmCmDsOfdmRxMerEntry88

Siblings (9)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.27.1.2.1 docsPnmCmControlObjects33
1.3.6.1.4.1.4491.2.1.27.1.2.2 docsPnmCmDsOfdmSymCapTable111
1.3.6.1.4.1.4491.2.1.27.1.2.3 docsPnmCmOfdmChanEstCoefTable19
1.3.6.1.4.1.4491.2.1.27.1.2.4 docsPnmCmDsConstDispMeasTable17
1.3.6.1.4.1.4491.2.1.27.1.2.6 docsPnmCmDsOfdmMerMarTable110
1.3.6.1.4.1.4491.2.1.27.1.2.7 docsPnmCmDsOfdmFecTable15
1.3.6.1.4.1.4491.2.1.27.1.2.8 docsPnmCmDsOfdmReqMERObjects1010
1.3.6.1.4.1.4491.2.1.27.1.2.9 docsPnmCmDsHistTable111
1.3.6.1.4.1.4491.2.1.27.1.2.10 docsPnmCmUsPreEqTable111